YB2 Series 2-Pole Explosion-Proof Motor
Two-pole flameproof squirrel-cage induction motor certified to Ex d IIB T4 for Zone 1 and Zone 2 hazardous areas containing Group IIB flammable gases and vapours. Running at approximately 2900 rpm on 380 V 50 Hz, this motor is the standard specification for high-speed pumps, compressors, and fans in petrochemical, pharmaceutical, and solvent-handling facilities where ignition sources must be eliminated.
Zone 1 / Zone 2
Speed: ~2900 rpm (2P)
Power: 0.75 – 132 kW
Protection: IP55
Insulation: Class F


Certified Flameproof Motor for Zone 1 and Zone 2 Hazardous Areas
The YB2 is Korea Ever-Power flameproof explosion-protected three-phase induction motor, certified to IEC 60079-1 for Ex d (flameproof enclosure) protection in hazardous areas. The motor enclosure is designed and tested to contain any internal ignition without the flame or pressure wave propagating to the surrounding atmosphere. All flame paths (shaft seals, terminal box joint, endshield-to-frame joints) are machined to certified gap dimensions and surface finish tolerances that prevent ignition of the external flammable atmosphere even in the event of an internal arc or short circuit.
The Group IIB classification covers the majority of industrial flammable gases and vapours including ethylene, propane, methane, hydrogen sulphide, propylene, and most light hydrocarbon fractions. The T4 temperature class (maximum surface temperature 135 °C) is the most commonly required classification for petrochemical and pharmaceutical applications. For applications involving hydrogen or acetylene (Group IIC), contact Korea Ever-Power for the IIC variant which uses tighter flame path tolerances.
The 2-pole YB2 covers 0.75 kW to 132 kW in frame sizes 80M through 315M. All units carry IP55 protection as standard (dust-tight and water-jet resistant), Class F insulation with Class B temperature-rise limits, and CE marking. Terminal boxes are oversized relative to the Y2 series to accommodate the larger cable glands required by hazardous area wiring regulations.
View the complete explosion-proof range at the Explosion-Proof Motors page, or compare with standard motors at Three-Phase Induction Motors.
YB2 2-Pole Model Specifications — Ex d IIB T4
All models: 2-pole, ~2900 rpm, 380 V 50 Hz, IP55, Class F insulation, Ex d IIB T4, Zone 1 and Zone 2.
| Model | Frame | kW | Full-Load A | rpm | η % | cosφ | Tst/Tn | Ist/In | kg |
|---|---|---|---|---|---|---|---|---|---|
| YB2-80M2-2 | 80M | 0.75 | 2.10 | 2840 | 73.0 | 0.83 | 2.2 | 6.5 | 22 |
| YB2-90S-2 | 90S | 1.1 | 2.96 | 2850 | 75.5 | 0.84 | 2.2 | 6.5 | 30 |
| YB2-90L-2 | 90L | 1.5 | 3.92 | 2855 | 77.5 | 0.84 | 2.2 | 7.0 | 38 |
| YB2-100L-2 | 100L | 2.2 | 5.50 | 2870 | 79.5 | 0.85 | 2.2 | 7.0 | 50 |
| YB2-112M-2 | 112M | 4.0 | 9.50 | 2880 | 83.0 | 0.85 | 2.2 | 7.0 | 72 |
| YB2-132S-2 | 132S | 5.5 | 12.70 | 2885 | 85.0 | 0.86 | 2.2 | 7.0 | 92 |
| YB2-132M-2 | 132M | 7.5 | 16.90 | 2890 | 86.5 | 0.87 | 2.2 | 7.0 | 116 |
| YB2-160M-2 | 160M | 11 | 23.80 | 2895 | 87.5 | 0.88 | 2.0 | 7.0 | 160 |
| YB2-160L-2 | 160L | 15 | 31.80 | 2900 | 88.5 | 0.88 | 2.0 | 7.0 | 195 |
| YB2-180M-2 | 180M | 18.5 | 38.20 | 2930 | 89.5 | 0.89 | 2.0 | 7.0 | 238 |
| YB2-200L-2 | 200L | 22 | 45.00 | 2940 | 90.0 | 0.89 | 2.0 | 7.0 | 295 |
| YB2-225M-2 | 225M | 30 | 60.00 | 2945 | 91.0 | 0.89 | 2.0 | 7.0 | 378 |
| YB2-250M-2 | 250M | 45 | 88.00 | 2950 | 92.0 | 0.90 | 2.0 | 7.0 | 490 |
| YB2-280S-2 | 280S | 55 | 106.00 | 2950 | 92.5 | 0.90 | 2.0 | 7.0 | 640 |
| YB2-315S-2 | 315S | 90 | 170.00 | 2955 | 93.0 | 0.90 | 1.8 | 7.0 | 870 |
| YB2-315M-2 | 315M | 132 | 245.00 | 2960 | 93.5 | 0.91 | 1.8 | 7.0 | 1080 |
Operating Conditions
| Ambient temperature | −20 °C to +40 °C |
| Altitude | ≤ 1000 m ASL |
| Supply voltage | 380 V ± 5% |
| Frequency | 50 Hz ± 1% |
| Mounting | IMB3 / IMB5 / IMB35 |
| Protection | IP55 |
| Insulation class | Class F |
| Temperature rise | Class B limit |
| Max surface temp | 135 °C (T4) |
Hazardous Area Certification
| Protection method | Ex d (flameproof) |
| Gas group | IIB |
| Temperature class | T4 (135 °C max) |
| Zone suitability | Zone 1, Zone 2 |
| Ex standard | IEC 60079-1 |
| Motor standard | IEC 60034 |
| Quality management | ISO 9001 |
| Marking | CE / Ex |
Typical Applications for YB2 2-Pole Explosion-Proof Motors
Petrochemical Pumps
API 610 centrifugal pumps for crude oil, naphtha, gasoline, and light hydrocarbon transfer in oil refineries and petrochemical complexes require Ex d IIB motors as the standard specification for Zone 1 pump hall areas where flammable vapour release is possible during normal operation.
|
Pharmaceutical Solvent Handling
Ethanol, acetone, and solvent transfer pumps in pharmaceutical manufacturing plants operate in Zone 1 areas classified under ATEX or IECEx regulations. The YB2 2-pole is the standard motor for high-speed solvent pump drives where Ex d IIB T4 covers all common pharmaceutical solvents.
|
Zone 1 Ventilation Fans
Forced-ventilation and fume-extraction fans in paint booths, tank farms, and chemical storage areas require Ex d motors because the fan circulates potentially flammable atmosphere across the motor. The 2-pole motor provides the high blade tip speed needed for efficient centrifugal fan operation in these duties.
|
|
⛽
Gas Compressor Auxiliaries
Lube oil pumps, seal gas booster compressors, and cooling fans on natural gas and LNG compressor trains operate in Zone 1 or Zone 2 areas and require Ex d IIB T4 motors as the primary protection method specified by most gas processing plant engineering standards.
|
🚢
Fuel Handling Systems
Jet fuel, diesel, and aviation spirit transfer pumps at fuel depots and airport fuelling systems require Ex d IIB motors with T4 temperature classification to cover the specific auto-ignition temperatures of aviation fuels under maximum ambient conditions.
|
🏭
Paint and Coating Lines
Spray booth fans, solvent circulation pumps, and paint mixing equipment in automotive and industrial coating facilities operate in Zone 1 spray areas and Zone 2 surrounding areas, requiring Ex d IIB T4 motors throughout the booth ventilation and fluid transfer systems.
|
Understanding Ex d IIB T4 Certification for the YB2 Motor
Ex d: Flameproof Enclosure
Ex d means the motor enclosure is designed to contain any internal electrical fault, arc, or ignition within the motor body without the resulting flame or pressure wave escaping to ignite the surrounding flammable atmosphere. All joints between motor parts (endshield to frame, shaft seals, terminal box cover) are machined to IEC 60079-1 certified gap length, gap width, and surface finish specifications. These dimensions are tested to ensure that hot gases from an internal explosion are cooled below the ignition temperature of the external atmosphere before they exit the enclosure.
Group IIB: Gas Classification
The IEC gas group classification system divides flammable gases by their minimum ignition energy and maximum safe gap (MESG). Group I is mining methane. Group IIA covers propane, methane, and ammonia. Group IIB covers ethylene, ethyl ether, hydrogen sulphide, propylene, and most light hydrocarbon vapours. Group IIC (the most demanding) covers hydrogen and acetylene. The YB2 IIB certification covers all Group IIA gases by upward compatibility, plus the IIB gases, making it suitable for the majority of petrochemical and pharmaceutical hazardous area applications. Where hydrogen or acetylene is specifically present, an IIC-certified motor is required.
T4: Surface Temperature Class
The temperature class (T1 through T6) specifies the maximum permissible surface temperature of the motor exterior under any operating condition including worst-case overload. T4 limits the maximum surface temperature to 135 °C. This covers most industrial flammable substances including ethanol (365 °C ignition temperature), acetone (465 °C), propane (470 °C), and ethylene (425 °C) with substantial margin. Substances with lower auto-ignition temperatures — such as carbon disulphide (90 °C) — require T5 or T6 rated motors. Korea Ever-Power can supply T5-rated variants on request for low-ignition-temperature applications.
Frequently Asked Questions — YB2 Series 2-Pole Explosion-Proof Motor
Request a Quote for YB2 2-Pole Explosion-Proof Motors
Specify power (kW), hazardous area zone, gas group, temperature class, and any national certification requirements. Learn about our quality standards on the About Us page.
Zusätzliche Informationen
| Editor | Cxm |
|---|