{"id":202,"date":"2026-07-09T08:53:14","date_gmt":"2026-07-09T08:53:14","guid":{"rendered":"https:\/\/industrialelectricmotor.net\/?p=202"},"modified":"2026-07-09T08:53:14","modified_gmt":"2026-07-09T08:53:14","slug":"explosion-proof-motor-for-wastewater-treatment-plant","status":"publish","type":"post","link":"https:\/\/industrialelectricmotor.net\/fi\/explosion-proof-motor-for-wastewater-treatment-plant\/","title":{"rendered":"R\u00e4j\u00e4hdyssuojattu moottori j\u00e4tevedenpuhdistamolle"},"content":{"rendered":"<div style=\"font-family: Arial,Helvetica,sans-serif; font-size: 16px; line-height: 1.8; color: #333; max-width: 100%; margin: 0 auto;\">\n<p><!-- HERO --><\/p>\n<div style=\"position: relative; background: linear-gradient(135deg,#071828 0%,#0a2240 45%,#0e2e58 70%,#0a1f35 100%); border-radius: 14px; margin: 0 0 40px; overflow: hidden; min-height: 320px;\">\n<div style=\"position: absolute; top: -60px; right: -40px; width: 420px; height: 420px; background: radial-gradient(circle,rgba(30,111,168,0.35) 0%,transparent 65%); pointer-events: none;\"><\/div>\n<div style=\"position: absolute; bottom: -80px; left: -60px; width: 360px; height: 360px; background: radial-gradient(circle,rgba(14,46,88,0.5) 0%,transparent 70%); pointer-events: none;\"><\/div>\n<div style=\"position: absolute; top: 0; left: 0; right: 0; height: 4px; background: linear-gradient(90deg,#1e6fa8,#5bb3f0,#1e6fa8);\"><\/div>\n<div style=\"position: relative; z-index: 2; padding: 52px 40px 50px;\">\n<div style=\"display: inline-flex; align-items: center; gap: 8px; margin-bottom: 18px;\">\n<div style=\"width: 24px; height: 3px; background: #5bb3f0; border-radius: 2px;\"><\/div>\n<p><span style=\"font-size: 10px; font-weight: 800; letter-spacing: 3px; text-transform: uppercase; color: #5bb3f0;\">Korea Ever-Power \u00b7 YB2-sarja \u00b7 J\u00e4tevedenpuhdistamon k\u00e4ytt\u00f6opas<\/span><\/p>\n<div style=\"width: 24px; height: 3px; background: #5bb3f0; border-radius: 2px;\"><\/div>\n<\/div>\n<h1 style=\"font-size: clamp(24px,4vw,40px); font-weight: 900; color: #fff; margin: 0 0 18px; line-height: 1.15; max-width: 740px; letter-spacing: -0.5px;\">R\u00e4j\u00e4hdyssuojattu moottori j\u00e4tevedenpuhdistamolle:<br \/>\n<span style=\"color: #5bb3f0;\">Lietteenpumpun, m\u00e4d\u00e4tt\u00e4j\u00e4n ja kaasuvy\u00f6hykkeen k\u00e4ytt\u00f6opas<\/span><\/h1>\n<p style=\"font-size: 16px; color: #b0d4f0; margin: 0 0 28px; max-width: 680px; line-height: 1.75;\">J\u00e4tevedenpuhdistamot k\u00e4sittelev\u00e4t samanaikaisesti useita vaarallisia aineita: m\u00e4d\u00e4tyksen aikana vapautuvaa rikkivety\u00e4 (H\u2082S) sis\u00e4lt\u00e4v\u00e4\u00e4 j\u00e4tevesilietett\u00e4, anaerobisissa m\u00e4d\u00e4ttimiss\u00e4 syntyv\u00e4\u00e4 biokaasua (p\u00e4\u00e4asiassa metaania) ja haihtuvia orgaanisia liuottimia sis\u00e4lt\u00e4v\u00e4\u00e4 teollisuusj\u00e4tevett\u00e4. Laitoksen moottorivaatimukset vaihtelevat sijainnin mukaan: anaerobiset m\u00e4d\u00e4tt\u00e4m\u00f6alueet vaativat r\u00e4j\u00e4hdyssuojattuja moottoreita metaanikaasualueille, H\u2082S:n uuttoalueet vaativat Ex d -sertifioinnin sulfidikaasuryhm\u00e4lle ja ulkona k\u00e4ytett\u00e4v\u00e4t lietepumppualueet vaativat IP55-luokan moottorit korroosionkest\u00e4vill\u00e4 pinnoitteilla. T\u00e4m\u00e4 opas kattaa Korea Ever-Power YB2 -sarjan j\u00e4tevedenpuhdistamojen moottorien t\u00e4ydelliset tekniset tiedot.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 8px;\"><span style=\"background: rgba(30,111,168,0.28); border: 1px solid rgba(91,179,240,0.4); border-radius: 20px; padding: 5px 14px; font-size: 12px; font-weight: bold; color: #c5e4f8;\">Ex d IIB T4 Biokaasu<\/span><br \/>\n<span style=\"background: rgba(30,111,168,0.18); border: 1px solid rgba(91,179,240,0.25); border-radius: 20px; padding: 5px 14px; font-size: 12px; font-weight: bold; color: #9fcee8;\">Vy\u00f6hyke 1, m\u00e4d\u00e4tt\u00e4m\u00f6alue<\/span><br \/>\n<span style=\"background: rgba(30,111,168,0.18); border: 1px solid rgba(91,179,240,0.25); border-radius: 20px; padding: 5px 14px; font-size: 12px; font-weight: bold; color: #9fcee8;\">IP55 ulkok\u00e4ytt\u00f6\u00f6n<\/span><br \/>\n<span style=\"background: rgba(30,111,168,0.18); border: 1px solid rgba(91,179,240,0.25); border-radius: 20px; padding: 5px 14px; font-size: 12px; font-weight: bold; color: #9fcee8;\">H\u2082S-kest\u00e4v\u00e4 pinnoite<\/span><br \/>\n<span style=\"background: rgba(30,111,168,0.18); border: 1px solid rgba(91,179,240,0.25); border-radius: 20px; padding: 5px 14px; font-size: 12px; font-weight: bold; color: #9fcee8;\">0,55\u2013200 kW<\/span><\/div>\n<\/div>\n<\/div>\n<p><!-- SPEC STRIP --><\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 10px; margin: 0 0 40px;\">\n<div style=\"flex: 1 1 120px; background: linear-gradient(135deg,#0a2240,#0e2e58); color: #fff; padding: 14px 12px; border-radius: 8px; border-top: 3px solid #1e6fa8; text-align: center;\">\n<div style=\"font-size: 17px; font-weight: 900; color: #5bb3f0; margin: 0 0 3px;\">IIB<\/div>\n<div style=\"font-size: 12px; font-weight: 600; color: #9fcee8;\">Metaani- ja biokaasuryhm\u00e4<\/div>\n<\/div>\n<div style=\"flex: 1 1 120px; background: linear-gradient(135deg,#0a2240,#0e2e58); color: #fff; padding: 14px 12px; border-radius: 8px; border-top: 3px solid #1e6fa8; text-align: center;\">\n<div style=\"font-size: 17px; font-weight: 900; color: #5bb3f0; margin: 0 0 3px;\">T4<\/div>\n<div style=\"font-size: 12px; font-weight: 600; color: #9fcee8;\">135 \u00b0C pintal\u00e4mp\u00f6tilaraja<\/div>\n<\/div>\n<div style=\"flex: 1 1 120px; background: linear-gradient(135deg,#0a2240,#0e2e58); color: #fff; padding: 14px 12px; border-radius: 8px; border-top: 3px solid #1e6fa8; text-align: center;\">\n<div style=\"font-size: 17px; font-weight: 900; color: #5bb3f0; margin: 0 0 3px;\">Vy\u00f6hyke 1<\/div>\n<div style=\"font-size: 12px; font-weight: 600; color: #9fcee8;\">Keittolan sis\u00e4tilat<\/div>\n<\/div>\n<div style=\"flex: 1 1 120px; background: linear-gradient(135deg,#0a2240,#0e2e58); color: #fff; padding: 14px 12px; border-radius: 8px; border-top: 3px solid #1e6fa8; text-align: center;\">\n<div style=\"font-size: 17px; font-weight: 900; color: #5bb3f0; margin: 0 0 3px;\">IP55<\/div>\n<div style=\"font-size: 12px; font-weight: 600; color: #9fcee8;\">Ulkona oleva lietealue<\/div>\n<\/div>\n<div style=\"flex: 1 1 120px; background: linear-gradient(135deg,#0a2240,#0e2e58); color: #fff; padding: 14px 12px; border-radius: 8px; border-top: 3px solid #1e6fa8; text-align: center;\">\n<div style=\"font-size: 17px; font-weight: 900; color: #5bb3f0; margin: 0 0 3px;\">H\u2082S<\/div>\n<div style=\"font-size: 12px; font-weight: 600; color: #9fcee8;\">Sulfidia kest\u00e4v\u00e4 pinnoite<\/div>\n<\/div>\n<\/div>\n<p><!-- HERO IMAGE --><\/p>\n<div style=\"margin: 0 0 40px;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto; max-height: 420px; object-fit: contain; border-radius: 10px; display: block; box-shadow: 0 6px 28px rgba(7,24,40,0.15); background: #f4f7ff;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/cat-explosion-proof-motor.webp\" alt=\"R\u00e4j\u00e4hdyssuojattu moottorik\u00e4ytt\u00f6inen j\u00e4tevedenpuhdistamo YB2 biokaasun m\u00e4d\u00e4tt\u00e4j\u00e4, vy\u00f6hyke 1, ATEX Ex d IIB T4, lietepumppu Korea Ever-Power\" width=\"800\" height=\"800\" title=\"\"><\/p>\n<div style=\"font-size: 13px; color: #666; margin: 8px 0 0; padding-left: 4px;\">Korea Ever-Power YB2 -sarjan Ex d IIB T4 -r\u00e4j\u00e4hdyssuojattu moottori \u2014 sertifioitu moottorispesifikaatio kaikkiin vy\u00f6hykkeiden 1 ja 2 sijainteihin anaerobisissa m\u00e4d\u00e4tt\u00e4j\u00e4rakennuksissa, biokaasun k\u00e4sittelyalueilla ja lietteen vedenpoistolaitoksissa j\u00e4tevedenpuhdistamoilla, joissa voi olla metaanin ja rikkivedyn kaasuseoksia.<\/div>\n<\/div>\n<p><!-- TOC --><\/p>\n<div style=\"background: linear-gradient(135deg,#f0f6ff,#e8f0fb); border-radius: 10px; padding: 26px 30px; margin: 0 0 44px; border-left: 4px solid #1e6fa8;\">\n<div style=\"font-size: 12px; font-weight: bold; color: #1e6fa8; letter-spacing: 2px; text-transform: uppercase; margin: 0 0 12px;\">Sis\u00e4llys<\/div>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(260px,1fr)); gap: 3px 24px;\"><a style=\"color: #0a2240; text-decoration: none; font-size: 14px; padding: 5px 0; border-bottom: 1px solid #d0dff0; display: block;\" href=\"#ww-hazards\">1. J\u00e4tevedenpuhdistamon vaarallisten kaasujen alueet<\/a><br \/>\n<a style=\"color: #0a2240; text-decoration: none; font-size: 14px; padding: 5px 0; border-bottom: 1px solid #d0dff0; display: block;\" href=\"#biogas-group\">2. Biokaasun ja H\u2082S-kaasuryhmien luokitus<\/a><br \/>\n<a style=\"color: #0a2240; text-decoration: none; font-size: 14px; padding: 5px 0; border-bottom: 1px solid #d0dff0; display: block;\" href=\"#digester-zone\">3. Anaerobisen m\u00e4d\u00e4tt\u00e4j\u00e4n vy\u00f6hykkeen luokittelu<\/a><br \/>\n<a style=\"color: #0a2240; text-decoration: none; font-size: 14px; padding: 5px 0; border-bottom: 1px solid #d0dff0; display: block;\" href=\"#sludge-ip\">4. Lietealueen IP55-luokitus ja korroosiosuojaus<\/a><br \/>\n<a style=\"color: #0a2240; text-decoration: none; font-size: 14px; padding: 5px 0; border-bottom: 1px solid #d0dff0; display: block;\" href=\"#h2s-corrosion\">5. H\u2082S-hy\u00f6kk\u00e4ys tavallisia moottoripinnoitteita vastaan<\/a><br \/>\n<a style=\"color: #0a2240; text-decoration: none; font-size: 14px; padding: 5px 0; border-bottom: 1px solid #d0dff0; display: block;\" href=\"#yb2-ww\">6. YB2 j\u00e4tevedenk\u00e4sittelysovelluksiin<\/a><br \/>\n<a style=\"color: #0a2240; text-decoration: none; font-size: 14px; padding: 5px 0; border-bottom: 1px solid #d0dff0; display: block;\" href=\"#ww-apps\">7. J\u00e4tevedenk\u00e4sittelysovellukset<\/a><br \/>\n<a style=\"color: #0a2240; text-decoration: none; font-size: 14px; padding: 5px 0; display: block;\" href=\"#faqA22\">8. Usein kysytyt kysymykset<\/a><\/div>\n<\/div>\n<p><!-- SECTION 1 --><\/p>\n<div id=\"ww-hazards\" style=\"margin: 0 0 48px;\">\n<h2 style=\"font-size: 26px; font-weight: 800; color: #0a2240; margin: 0 0 16px; padding-bottom: 10px; border-bottom: 2px solid #d0dff0;\">1. J\u00e4tevedenpuhdistamon vaarallisten kaasujen vy\u00f6hykkeet<\/h2>\n<p style=\"margin: 0 0 16px;\">Nykyaikaisella j\u00e4tevedenpuhdistamolla on useita erillisi\u00e4 alueita, joilla on erilaisia \u200b\u200bvaarallisten kaasujen riskej\u00e4. Laitoksen kaikki alueet eiv\u00e4t vaadi r\u00e4j\u00e4hdyssuojattuja moottoreita \u2013 tavallisen kunnallisen j\u00e4tevedenpuhdistamon ilmastusaltaat, selkeyttimet ja kemikaalien annostelualueet toimivat luokittelemattomissa olosuhteissa \u2013 mutta biokaasua, lietett\u00e4 ja teollisuusj\u00e4tevesi\u00e4 k\u00e4sittelev\u00e4t alueet vaativat huolellisen vaarallisten alueiden luokittelun.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(260px,1fr)); gap: 14px; margin: 0 0 20px;\">\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-top: 3px solid #dc2626; border-radius: 8px; padding: 14px 16px;\">\n<div style=\"font-size: 14px; font-weight: bold; color: #dc2626; margin: 0 0 6px;\">Vy\u00f6hyke 1 \u2014 Keittoastian sis\u00e4puoli ja viereiset alueet<\/div>\n<p style=\"font-size: 13px; color: #444; margin: 0; line-height: 1.65;\">Anaerobisen m\u00e4d\u00e4tt\u00e4m\u00f6n sis\u00e4tilat, biokaasun varastopallojen sis\u00e4tilat, biokaasuputkik\u00e4yt\u00e4v\u00e4t ja alueet 1 metrin s\u00e4teell\u00e4 biokaasuventtiilist\u00e4 ja liitosryhmist\u00e4. Biokaasu on p\u00e4\u00e4asiassa metaania (60 - 70%), jossa on CO\u2082:ta ja j\u00e4\u00e4mi\u00e4 H\u2082S:st\u00e4. Metaani on luokiteltu luokkaa IIA (itsesyttymisl\u00e4mp\u00f6tila 537 \u00b0C). Yhdistetty biokaasuseos on luokiteltu IIB H\u2082S-pitoisuuden vuoksi. Kaikkien vy\u00f6hykkeen 1 m\u00e4d\u00e4tt\u00e4m\u00f6iden moottoreiden on oltava YB2 Ex d IIB T4 -luokan. T\u00e4m\u00e4 sis\u00e4lt\u00e4\u00e4 biokaasukompressorien moottorit, m\u00e4d\u00e4tt\u00e4m\u00f6n sekoituspumppujen moottorit ja kaikki m\u00e4d\u00e4tt\u00e4m\u00f6rakennukseen asennetut s\u00e4hk\u00f6laitteet.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-top: 3px solid #d97706; border-radius: 8px; padding: 14px 16px;\">\n<div style=\"font-size: 14px; font-weight: bold; color: #d97706; margin: 0 0 6px;\">Vy\u00f6hyke 2 \u2014 Keittolan rakennuksen ulkoreuna<\/div>\n<p style=\"font-size: 13px; color: #444; margin: 0; line-height: 1.65;\">M\u00e4d\u00e4tt\u00e4j\u00e4rakennuksen ulkopuolinen alue 3 metrin s\u00e4teell\u00e4 mist\u00e4 tahansa ilmanvaihtoaukosta, huoltoluukusta tai putkisis\u00e4\u00e4nk\u00e4ynnist\u00e4 on tyypillisesti vy\u00f6hyke 2. Biokaasua voi olla l\u00e4sn\u00e4 t\u00e4ll\u00e4 vy\u00f6hykkeell\u00e4 huoltotoimien, ilmanvaihtoj\u00e4rjestelm\u00e4n poikkeavuuksien tai laippaliitoksista per\u00e4isin olevien pienten kaasuvuotojen aikana. Vy\u00f6hykkeen 2 vy\u00f6hykkeen alueilla ulkomoottoreiden on oltava YB2 Ex d IIB T4 - tai vastaavia vy\u00f6hykkeen 2 mukaisia \u200b\u200bsertifioituja moottoreita \u2013 vakiomallisia Y2-moottoreita ei hyv\u00e4ksyt\u00e4 edes ulkona vy\u00f6hykkeen 2 alueilla.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-top: 3px solid #1e6fa8; border-radius: 8px; padding: 14px 16px;\">\n<div style=\"font-size: 14px; font-weight: bold; color: #0a2240; margin: 0 0 6px;\">H\u2082S-altistus \u2014 Luokittelematon, mutta sy\u00f6vytt\u00e4v\u00e4<\/div>\n<p style=\"font-size: 13px; color: #444; margin: 0; line-height: 1.65;\">Lietteest\u00e4 vapautuu rikkivety\u00e4 pitoisuuksina, jotka ovat tyypillisesti r\u00e4j\u00e4hdysalueen alapuolella (LEL 4% ilmassa), mutta myrkyllisen hajukynnyksen yl\u00e4puolella ja tason yl\u00e4puolella, joka hy\u00f6kk\u00e4\u00e4 aggressiivisesti kupari-, hopea- ja rautapohjaisia \u200b\u200bpinnoitteita vastaan. Lietteen sakeutusalueita, vedenpoistorakennuksia ja lietteen kuivausalustoja ei v\u00e4ltt\u00e4m\u00e4tt\u00e4 luokitella r\u00e4j\u00e4hdysvaarallisiksi vy\u00f6hykkeiksi (jos H\u2082S-pitoisuudet pysyv\u00e4t alle 25% LEL -arvon), mutta kaikissa n\u00e4ill\u00e4 alueilla olevissa moottoreissa on oltava H\u2082S-kest\u00e4v\u00e4t pinnoitteet ja tiivistetyt liit\u00e4nt\u00e4kotelot s\u00e4hk\u00f6komponenttien nopean korroosion est\u00e4miseksi.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- SECTION 2 --><\/p>\n<div id=\"biogas-group\" style=\"margin: 0 0 48px;\">\n<h2 style=\"font-size: 26px; font-weight: 800; color: #0a2240; margin: 0 0 16px; padding-bottom: 10px; border-bottom: 2px solid #d0dff0;\">2. Biokaasun ja H\u2082S-kaasuryhmien luokitus<\/h2>\n<div style=\"background: linear-gradient(135deg,#0a2240,#0e2e58); border-radius: 10px; padding: 20px 26px; margin: 0 0 22px; color: #fff;\">\n<div style=\"font-size: 11px; font-weight: bold; letter-spacing: 2px; text-transform: uppercase; color: #5bb3f0; margin: 0 0 12px;\">J\u00e4tevesikaasujen vaaratilanteiden yhteenveto<\/div>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(200px,1fr)); gap: 14px; font-size: 13px;\">\n<div style=\"border-left: 3px solid #1e6fa8; padding-left: 12px;\">\n<div style=\"font-weight: bold; color: #5bb3f0; margin: 0 0 4px;\">Metaani (CH\u2084)<\/div>\n<div style=\"color: #b0d4f0; line-height: 1.65;\">Kaasuryhm\u00e4: IIA<br \/>\nLEL: 5% v\/v ilmassa<br \/>\nYlin sallittu k\u00e4ytt\u00f6ik\u00e4: 15% v\/v<br \/>\nItsesyttymispiste: 537 \u00b0C<br \/>\nVaadittu T-luokka: T1<br \/>\nYB2 IIB T4: kattaa IIA:n<\/div>\n<\/div>\n<div style=\"border-left: 3px solid #d97706; padding-left: 12px;\">\n<div style=\"font-weight: bold; color: #f59e0b; margin: 0 0 4px;\">Vetysulfidi (H\u2082S)<\/div>\n<div style=\"color: #b0d4f0; line-height: 1.65;\">Kaasuryhm\u00e4: IIB<br \/>\nLEL: 4% v\/v ilmassa<br \/>\nUEL: 46% v\/v<br \/>\nItsesyttymispiste: 260 \u00b0C<br \/>\nVaadittu T-luokka: T3<br \/>\nYB2 IIB T4: kattaa IIB T3:n<\/div>\n<\/div>\n<div style=\"border-left: 3px solid #1e6fa8; padding-left: 12px;\">\n<div style=\"font-weight: bold; color: #5bb3f0; margin: 0 0 4px;\">Biokaasuseos<\/div>\n<div style=\"color: #b0d4f0; line-height: 1.65;\">60\u201370% CH\u2084, 30\u201340% CO\u2082, 0,5\u20132% H\u2082S<br \/>\nH\u2082S-sis\u00e4lt\u00f6 ohjaa ryhm\u00e4n IIB-tasolle<br \/>\nT-luokka: T3 H\u2082S-komponentille<br \/>\nYB2 IIB T4 kattaa kaiken biokaasun<br \/>\nATEX- ja IECEx-sertifioitu<\/div>\n<\/div>\n<div style=\"border-left: 3px solid #4ade80; padding-left: 12px;\">\n<div style=\"font-weight: bold; color: #4ade80; margin: 0 0 4px;\">YB2 IIB T4 -kattavuus<\/div>\n<div style=\"color: #b0d4f0; line-height: 1.65;\">Ryhm\u00e4 IIB kattaa metaanin (IIA) ja H\u2082S:n (IIB). T4-l\u00e4mp\u00f6tila 135 \u00b0C:n pinnalla tarjoaa riitt\u00e4v\u00e4n marginaalin H\u2082S:n itsesyttymisen (260 \u00b0C) yl\u00e4puolella. Yksi YB2 IIB T4 -spesifikaatio kattaa kaikki j\u00e4tevesien biokaasualueiden vaatimukset.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- SECTION 3 --><\/p>\n<div id=\"digester-zone\" style=\"margin: 0 0 48px;\">\n<h2 style=\"font-size: 26px; font-weight: 800; color: #0a2240; margin: 0 0 16px; padding-bottom: 10px; border-bottom: 2px solid #d0dff0;\">3. Anaerobisen m\u00e4d\u00e4tt\u00e4j\u00e4n vy\u00f6hykkeiden luokittelu k\u00e4yt\u00e4nn\u00f6ss\u00e4<\/h2>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 16px; margin: 0 0 20px;\">\n<div style=\"background: #f4f7ff; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #1e6fa8;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">Keitt\u00e4j\u00e4rakennus \u2014 Vy\u00f6hyke 1 koko alueella<\/div>\n<p style=\"font-size: 13px; color: #444; margin: 0; line-height: 1.65;\">Katettu m\u00e4d\u00e4tt\u00e4m\u00f6rakennus (yleinen kylm\u00e4ss\u00e4 ilmastossa, jossa m\u00e4d\u00e4tt\u00e4j\u00e4\u00e4 on suojattava j\u00e4\u00e4tymiselt\u00e4) luokitellaan sis\u00e4tiloiltaan vy\u00f6hykkeeksi 1, koska biokaasua voi ker\u00e4\u00e4nty\u00e4 rakennuksen vaippaan r\u00e4j\u00e4hdysherkkin\u00e4 pitoisuuksina, jos ilmanvaihto pett\u00e4\u00e4 tai m\u00e4d\u00e4tt\u00e4m\u00f6n huoltot\u00f6iden aikana. Kaikkien m\u00e4d\u00e4tt\u00e4m\u00f6rakennuksen sis\u00e4ll\u00e4 olevien moottoreiden \u2013 lietteenkierr\u00e4tyspumppujen, sekoituspumppujen k\u00e4ytt\u00f6laitteiden, kaasukompressorien k\u00e4ytt\u00f6laitteiden ja l\u00e4mm\u00f6nvaihdinpumppujen k\u00e4ytt\u00f6laitteiden \u2013 on oltava tyypilt\u00e4\u00e4n YB2 Ex d IIB T4. S\u00e4hk\u00f6luokitus koskee my\u00f6s rakennuksen rajojen sis\u00e4puolella sijaitsevien k\u00e4yt\u00e4vien ja huoltoalueiden moottoreita.<\/p>\n<\/div>\n<div style=\"background: #f4f7ff; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #5bb3f0;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">Avoin m\u00e4d\u00e4tt\u00e4m\u00f6 \u2014 Vy\u00f6hyke 1 kannen yl\u00e4puolella<\/div>\n<p style=\"font-size: 13px; color: #444; margin: 0; line-height: 1.65;\">Munanmuotoisissa tai sylinterim\u00e4isiss\u00e4 m\u00e4d\u00e4tt\u00e4jiss\u00e4, joissa on kelluva kaasukansi, vy\u00f6hyke 1 sijaitsee kaasukannen yl\u00e4puolella ja 1 metrin s\u00e4teell\u00e4 kaasun ylipaineventtiilist\u00e4, kaasun ulostuloliit\u00e4nn\u00e4st\u00e4 ja pinnankorkeuden mittausliit\u00e4nn\u00f6ist\u00e4. Vy\u00f6hyke 2 ulottuu 1\u20133 metri\u00e4 vy\u00f6hykkeen 1 rajan ulkopuolelle. Vy\u00f6hykkeen 1 rajojen sis\u00e4puolella m\u00e4d\u00e4tt\u00e4j\u00e4n sein\u00e4\u00e4n tai katolle asennettujen ulkoisten sekoitinmoottorien on oltava YB2 Ex d IIB T4 -luokan. M\u00e4d\u00e4tt\u00e4j\u00e4n sein\u00e4ll\u00e4 olevat ulkoiset sekoitinmoottorit voivat sijaita vy\u00f6hykkeell\u00e4 2, jos niiden asennuspaikka on yli 1 metrin p\u00e4\u00e4ss\u00e4 kaasun ulostulosta; varmista t\u00e4m\u00e4 m\u00e4d\u00e4tt\u00e4j\u00e4n suunnittelun vaarallisen alueen luokituspiirustuksesta.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- SECTION 4 --><\/p>\n<div id=\"sludge-ip\" style=\"margin: 0 0 48px;\">\n<h2 style=\"font-size: 26px; font-weight: 800; color: #0a2240; margin: 0 0 16px; padding-bottom: 10px; border-bottom: 2px solid #d0dff0;\">4. Lietteenpumppausalueen IP55-luokitus ja korroosiosuojaus<\/h2>\n<p style=\"margin: 0 0 16px;\">Luokiteltujen biokaasualueiden ulkopuoliset lietteenk\u00e4sittelyalueet ovat edelleen haastavia moottoriymp\u00e4rist\u00f6j\u00e4: ulkoasennus, joka altistuu sateelle ja letkupesulle; H\u2082S-ilmakeh\u00e4, jonka pitoisuus on alle LEL:n, mutta on aggressiivisesti sy\u00f6vytt\u00e4v\u00e4\u00e4 (1\u201350 ppm H\u2082S); ja betonipintojen s\u00e4\u00e4nn\u00f6llinen letkupesu vedell\u00e4, joka sis\u00e4lt\u00e4\u00e4 lietett\u00e4 ja k\u00e4sittelykemikaaleja. IP55 on v\u00e4himm\u00e4iskotelointiluokka, ja korroosionkest\u00e4v\u00e4 pinnoite on v\u00e4ltt\u00e4m\u00e4t\u00f6n moottoreille n\u00e4ill\u00e4 alueilla, vaikka r\u00e4j\u00e4hdyssuojaussertifikaattia ei vaadittaisikaan.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(260px,1fr)); gap: 14px; margin: 0 0 0;\">\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-left: 4px solid #1e6fa8; border-radius: 6px; padding: 14px 16px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">IP55 ulkotiloihin tarkoitettuihin lietealueisiin<\/div>\n<p style=\"font-size: 13px; color: #444; margin: 0; line-height: 1.65;\">Ulkona sijaitsevien lietteenk\u00e4sittelyalueiden lietepumppuasemien, sakeuttamislaitteiden, vedenpoistopuristimien ja linkok\u00e4ytt\u00f6jen kotelointiluokan on oltava v\u00e4hint\u00e4\u00e4n IP55. Betonipintojen ja -laitteiden letkupesu ohjaa vesisuihkuja s\u00e4\u00e4nn\u00f6llisesti moottorikoteloihin. IP55-suojaus vesisuihkuja vastaan \u200b\u200best\u00e4\u00e4 veden p\u00e4\u00e4syn sis\u00e4\u00e4n, mik\u00e4 voisi aiheuttaa eristyksen heikkenemist\u00e4 H\u2082S-atmosf\u00e4\u00e4riss\u00e4.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-left: 4px solid #1e6fa8; border-radius: 6px; padding: 14px 16px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">Valurauta- vs. alumiinirunko H\u2082S:ss\u00e4<\/div>\n<p style=\"font-size: 13px; color: #444; margin: 0; line-height: 1.65;\">Valurautaiset rungot (vakiona YB2 Ex d -sarjassa IEC 112 -standardin mukaisesti ja sit\u00e4 korkeammissa) kest\u00e4v\u00e4t H\u2082S-korroosiota paremmin kuin maalatut alumiinirungot, joita k\u00e4ytet\u00e4\u00e4n tavallisissa Y2-moottoreissa IEC 100 -standardiin asti. Kun maalipinnoite rikkoutuu \u2013 mekaanisen iskun tai UV-s\u00e4teilyn seurauksena \u2013 paljastunut alumiini hapettuu ja H\u2082S kiihdytt\u00e4\u00e4 korroosiota. YB2-valurautainen runko, jossa on merik\u00e4ytt\u00f6\u00f6n soveltuva epoksipohjamaali ja polyuretaanipintamaali, tarjoaa erinomaisen pitk\u00e4n k\u00e4ytt\u00f6i\u00e4n H\u2082S-ymp\u00e4rist\u00f6iss\u00e4.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-left: 4px solid #5bb3f0; border-radius: 6px; padding: 14px 16px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">Suljettu liit\u00e4nt\u00e4kotelo H\u2082S:lle<\/div>\n<p style=\"font-size: 13px; color: #444; margin: 0; line-height: 1.65;\">H\u2082S sy\u00f6vytt\u00e4\u00e4 nopeasti kuparikaapelip\u00e4\u00e4tteit\u00e4 ja messinkisi\u00e4 kaapelitiivisteholkkeja \u2013 liittimien pinnoille muodostuu kuparisulfidikerrostumia, jotka lis\u00e4\u00e4v\u00e4t kosketusvastusta ja voivat aiheuttaa liitoksen ylikuumenemisen. YB2-tiivistetty IP55-liit\u00e4nt\u00e4rasia est\u00e4\u00e4 H\u2082S:n p\u00e4\u00e4syn liittimiin ja sy\u00f6vytt\u00e4misen niihin. K\u00e4yt\u00e4 tinattuja kupari- tai ruostumattomasta ter\u00e4ksest\u00e4 valmistettuja liitinosia, jos H\u2082S-pitoisuuksien odotetaan olevan yli 10 ppm.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- SECTION 5 --><\/p>\n<div id=\"h2s-corrosion\" style=\"margin: 0 0 48px;\">\n<h2 style=\"font-size: 26px; font-weight: 800; color: #0a2240; margin: 0 0 16px; padding-bottom: 10px; border-bottom: 2px solid #d0dff0;\">5. H\u2082S-hy\u00f6kk\u00e4ys tavallisia moottoripinnoitteita vastaan<\/h2>\n<div style=\"background: linear-gradient(135deg,#0a2240,#0e2e58); border-radius: 10px; padding: 18px 24px; margin: 0 0 22px; color: #fff;\">\n<div style=\"font-size: 11px; font-weight: bold; letter-spacing: 2px; text-transform: uppercase; color: #5bb3f0; margin: 0 0 10px;\">Vakiomoottori vs. YB2 j\u00e4tevesien H\u2082S-ymp\u00e4rist\u00f6ss\u00e4<\/div>\n<div style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 18px; font-size: 13px;\">\n<div>\n<div style=\"color: #f87171; font-weight: bold; margin: 0 0 5px;\">Vakiokokoinen Y2-alumiinimoottori H\u2082S-lietealueella:<\/div>\n<div style=\"color: #b0d4f0; line-height: 1.7;\">Vuosi 1: Maalin kupliminen naarmuissa ja pultinreikien reunoissa H\u2082S-hapon aiheuttamasta maalikalvon alla \u2192 Vuosi 2: Alumiinin pistekorroosiota n\u00e4kyviss\u00e4, valkoisia oksidikerrostumia rungon pinnalla \u2192 Vuosi 3: Vakavaa pistekorroosiota rungon sein\u00e4m\u00e4n l\u00e4pi joillakin alueilla, eristysvastus alkaa laskea H\u2082S:n ja kosteuden p\u00e4\u00e4syn vuoksi \u2192 Vuosi 4\u20135: Moottorin vaihto tarpeen.<\/div>\n<\/div>\n<div>\n<div style=\"color: #4ade80; font-weight: bold; margin: 0 0 5px;\">YB2-valurauta meriepoksipinnoitteella:<\/div>\n<div style=\"color: #b0d4f0; line-height: 1.7;\">Vuosi 1\u20135: Pinnoitteen eheys s\u00e4ilyy; H\u2082S ei saavuta valurauta-alustaa \u2192 Vuosi 5: Paikkamaalaus levitet\u00e4\u00e4n huoltov\u00e4lin aikana kaikkiin pieniin iskuvaurioihin \u2192 Vuosi 10+: Moottorin k\u00e4ytt\u00f6 jatkuu vuosittaisen tarkastuksen ja paikkausmaalauksen j\u00e4lkeen; IP55-tiivistetty liit\u00e4nt\u00e4kotelo est\u00e4\u00e4 H\u2082S-hy\u00f6kk\u00e4yksen kuparikaapelip\u00e4\u00e4tteisiin koko k\u00e4ytt\u00f6i\u00e4n ajan.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p style=\"font-size: 14px; color: #444; margin: 0;\">YB2-moottorin valitsemisen taloudelliset perustelut H\u2082S-j\u00e4tevesiymp\u00e4rist\u00f6iss\u00e4 ovat vakuuttavat, vaikka r\u00e4j\u00e4hdyssuojausta ei teknisesti vaadittaisi. YB2-valurautamoottorin 2\u20133 kertaa pidempi k\u00e4ytt\u00f6ik\u00e4 H\u2082S-atmosf\u00e4\u00e4riss\u00e4 tavalliseen Y2-alumiinimoottoriin verrattuna s\u00e4\u00e4st\u00e4\u00e4 enemm\u00e4n vaihto- ja ty\u00f6voimakustannuksissa kuin YB2-moottorin alkuper\u00e4inen lis\u00e4hinta ensimm\u00e4isen vaihtojakson aikana.<\/p>\n<\/div>\n<p><!-- SECTION 6 --><\/p>\n<div id=\"yb2-ww\" style=\"margin: 0 0 48px;\">\n<h2 style=\"font-size: 26px; font-weight: 800; color: #0a2240; margin: 0 0 16px; padding-bottom: 10px; border-bottom: 2px solid #d0dff0;\">6. Korea Ever-Power YB2 j\u00e4teveden k\u00e4sittelyyn<\/h2>\n<div style=\"display: flex; flex-wrap: wrap; gap: 22px; align-items: flex-start;\">\n<div style=\"flex: 1 1 280px;\">\n<p style=\"font-size: 15px; color: #444; margin: 0 0 14px; line-height: 1.7;\">Korea Ever-Power YB2 Ex d IIB T4 tarjoaa yhden moottorin spesifikaation, joka kattaa sek\u00e4 biokaasualueiden vy\u00f6hykkeen 1\/2 r\u00e4j\u00e4hdyssuojauksen ett\u00e4 H\u2082S-lietteen k\u00e4sittelyalueilla tarvittavan erinomaisen korroosionkest\u00e4vyyden. Valurautainen IP55-kotelo kest\u00e4\u00e4 H\u2082S-korroosiota yli 10 vuoden k\u00e4ytt\u00f6i\u00e4n ajan j\u00e4tevesiymp\u00e4rist\u00f6iss\u00e4. Ex d IIB T4 -sertifiointi kattaa sek\u00e4 metaani- (IIA) ett\u00e4 rikkivety (IIB) -kaasuryhm\u00e4t yhdell\u00e4 moottorityypill\u00e4, mik\u00e4 yksinkertaistaa moottorispesifikaatiota ja varaosien varastointia koko j\u00e4tevesilaitoksessa. Koko YB2-valikoima on... <a style=\"color: #1e6fa8; font-weight: 600;\" href=\"https:\/\/industrialelectricmotor.net\/fi\/tuote-osasto\/explosion-proof-motors\/\">r\u00e4j\u00e4hdyssuojattu moottoriosa<\/a>Jos j\u00e4tevesilaitoksen pumppu- ja puhallinmoottorien teho on yli 75 kW, ota yhteytt\u00e4 <a style=\"color: #1e6fa8; font-weight: 600;\" href=\"https:\/\/industrialelectricmotor.net\/fi\/contact-us\/\">Korea Ever-Power<\/a>.<\/p>\n<\/div>\n<div style=\"flex: 1 1 240px;\">\n<div style=\"background: linear-gradient(135deg,#0a2240,#0e2e58); border-radius: 10px; padding: 18px 20px; color: #fff;\">\n<div style=\"font-size: 11px; font-weight: bold; letter-spacing: 2px; text-transform: uppercase; color: #5bb3f0; margin: 0 0 12px;\">YB2 \u2014 J\u00e4tevesilaitoksen tiedot<\/div>\n<table style=\"width: 100%; border-collapse: collapse; font-size: 13px;\">\n<tbody>\n<tr>\n<td style=\"padding: 5px 0; color: #9fcee8; border-bottom: 1px solid rgba(91,179,240,0.15);\">Sertifiointi<\/td>\n<td style=\"padding: 5px 0; font-weight: 600; color: #5bb3f0; border-bottom: 1px solid rgba(91,179,240,0.15);\">ATEX + IECEx Ex d IIB T4<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 5px 0; color: #9fcee8; border-bottom: 1px solid rgba(91,179,240,0.15);\">Kaasuvakuutus<\/td>\n<td style=\"padding: 5px 0; font-weight: 600; border-bottom: 1px solid rgba(91,179,240,0.15);\">Metaani IIA + H\u2082S IIB<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 5px 0; color: #9fcee8; border-bottom: 1px solid rgba(91,179,240,0.15);\">Vy\u00f6hykkeen soveltuvuus<\/td>\n<td style=\"padding: 5px 0; font-weight: 600; border-bottom: 1px solid rgba(91,179,240,0.15);\">Vy\u00f6hyke 1 ja vy\u00f6hyke 2<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 5px 0; color: #9fcee8; border-bottom: 1px solid rgba(91,179,240,0.15);\">Kehys<\/td>\n<td style=\"padding: 5px 0; font-weight: 600; border-bottom: 1px solid rgba(91,179,240,0.15);\">Valurauta (H\u2082S-kest\u00e4v\u00e4)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 5px 0; color: #9fcee8; border-bottom: 1px solid rgba(91,179,240,0.15);\">IP-luokitus<\/td>\n<td style=\"padding: 5px 0; font-weight: 600; border-bottom: 1px solid rgba(91,179,240,0.15);\">IP55<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 5px 0; color: #9fcee8; border-bottom: 1px solid rgba(91,179,240,0.15);\">Pinnoite<\/td>\n<td style=\"padding: 5px 0; font-weight: 600; border-bottom: 1px solid rgba(91,179,240,0.15);\">Meriepoksi + polyuretaani<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 5px 0; color: #9fcee8; border-bottom: 1px solid rgba(91,179,240,0.15);\">Tehoalue<\/td>\n<td style=\"padding: 5px 0; font-weight: 600; border-bottom: 1px solid rgba(91,179,240,0.15);\">0,55\u2013200 kW<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 5px 0; color: #9fcee8;\">Pintal\u00e4mp\u00f6tila<\/td>\n<td style=\"padding: 5px 0; font-weight: 600;\">T4 = enint\u00e4\u00e4n 135 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- SECTION 7 --><\/p>\n<div id=\"ww-apps\" style=\"margin: 0 0 48px;\">\n<h2 style=\"font-size: 26px; font-weight: 800; color: #0a2240; margin: 0 0 16px; padding-bottom: 10px; border-bottom: 2px solid #d0dff0;\">7. J\u00e4tevedenpuhdistamon sovellukset<\/h2>\n<table style=\"width: 100%; border-collapse: collapse; margin: 0 0 22px;\">\n<tbody>\n<tr>\n<td style=\"width: 50%; padding: 0 12px 0 0; vertical-align: top;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 10px; display: block; margin: 0 0 12px; box-shadow: 0 3px 14px rgba(10,34,64,0.10);\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/app-chemical-plant.webp\" alt=\"R\u00e4j\u00e4hdyssuojattu moottorik\u00e4ytt\u00f6inen j\u00e4tevedenpuhdistamo biokaasulle, vy\u00f6hykkeelle 1, lietepumppu YB2 ATEX Korea Ever-Power\" width=\"800\" height=\"500\" title=\"\"><\/p>\n<div style=\"background: #f4f7ff; border-radius: 8px; padding: 14px 16px; border: 1px solid #d0dff0;\">\n<div style=\"font-weight: bold; color: #0a2240; margin: 0 0 5px; font-size: 14px;\">Anaerobisen m\u00e4d\u00e4tt\u00e4j\u00e4n sekoitus ja kaasun k\u00e4sittely<\/div>\n<p style=\"font-size: 13px; color: #555; margin: 0; line-height: 1.6;\">M\u00e4d\u00e4tt\u00e4j\u00e4n lietteen kierr\u00e4tyspumppujen k\u00e4ytt\u00f6laitteet (5,5\u201322 kW, vy\u00f6hyke 1), biokaasun kierr\u00e4tyskompressorien moottorit (7,5\u201330 kW, vy\u00f6hyke 1), kaasusekoitussuutinpumppujen k\u00e4ytt\u00f6laitteet (3,0\u201311 kW, vy\u00f6hyke 1) ja m\u00e4d\u00e4tt\u00e4j\u00e4n l\u00e4mm\u00f6nvaihdinpumppujen k\u00e4ytt\u00f6laitteet (1,5\u20137,5 kW, vy\u00f6hyke 1 tai 2). Kaikkien on oltava YB2 Ex d IIB T4 -luokan mukaisia. M\u00e4d\u00e4tt\u00e4j\u00e4rakennuksissa, joissa on mekaaninen ilmanvaihto, my\u00f6s ilmanvaihtopuhaltimien moottorit ovat vy\u00f6hykkeell\u00e4 1, jos ne on asennettu rakennuksen sis\u00e4lle, ja niiden on oltava YB2-sertifioituja.<\/p>\n<\/div>\n<\/td>\n<td style=\"width: 50%; padding: 0 0 0 12px; vertical-align: top;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 10px; display: block; margin: 0 0 12px; box-shadow: 0 3px 14px rgba(10,34,64,0.10);\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/app-hvac-pump-room.webp\" alt=\"R\u00e4j\u00e4hdyssuojattu moottorilietepumppu H2S-ulkoj\u00e4teveden vedenpoistoon YB2 IP55 Korea Ever-Power\" width=\"800\" height=\"500\" title=\"\"><\/p>\n<div style=\"background: #f4f7ff; border-radius: 8px; padding: 14px 16px; border: 1px solid #d0dff0;\">\n<div style=\"font-weight: bold; color: #0a2240; margin: 0 0 5px; font-size: 14px;\">Lietteen k\u00e4sittely ja vedenpoisto<\/div>\n<p style=\"font-size: 13px; color: #555; margin: 0; line-height: 1.6;\">Raakalietepumppujen k\u00e4ytt\u00f6moottorit (3,0\u201322 kW), sakeuttamislaitteen haran k\u00e4ytt\u00f6moottorit (0,75\u20135,5 kW), hihnapuristimen ja sentrifugin sy\u00f6tt\u00f6pumppujen moottorit (2,2\u201315 kW) ja lietekakkukuljettimien k\u00e4ytt\u00f6moottorit (0,55\u20133,0 kW). N\u00e4it\u00e4 alueita ei v\u00e4ltt\u00e4m\u00e4tt\u00e4 ole luokiteltu r\u00e4j\u00e4hdysvaarallisiksi, mutta ne edellytt\u00e4v\u00e4t H\u2082S-kest\u00e4v\u00e4\u00e4 pinnoitetta ja IP55-luokitusta. YB2 tarjoaa sek\u00e4 r\u00e4j\u00e4hdyssuojauksen ett\u00e4 korroosionkest\u00e4vyyden yhten\u00e4 moottorispesifikaationa koko laitoksessa.<\/p>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(200px,1fr)); gap: 12px;\">\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-radius: 8px; padding: 14px;\">\n<div style=\"font-size: 14px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">Biokaasun CHP-moottorin apulaitteet<\/div>\n<p style=\"font-size: 13px; color: #555; margin: 0; line-height: 1.6;\">Biokaasulla tuotettujen s\u00e4hk\u00f6n ja l\u00e4mm\u00f6n yhteistuotantolaitosten (CHP) moottorin j\u00e4\u00e4hdytysvesipumppujen k\u00e4ytt\u00f6laitteet ja konehuoneen ilmanvaihtopuhaltimet. Konehuone on vy\u00f6hyke 1 biokaasumoottorin kotelon sis\u00e4ll\u00e4 ja vy\u00f6hyke 2 konehuoneen alueella. YB2 1,5\u201311 kW j\u00e4\u00e4hdytyspumppujen ja puhaltimien k\u00e4ytt\u00f6laitteille konehuoneen rajojen sis\u00e4ll\u00e4.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-radius: 8px; padding: 14px;\">\n<div style=\"font-size: 14px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">Biokaasun jalostuslaitos<\/div>\n<p style=\"font-size: 13px; color: #555; margin: 0; line-height: 1.6;\">Biometaanin jalostuslaitokset (paineenvaihtelun absorptio tai kalvoerotus) puristavat biokaasun verkkoon injektoitavaksi. Kompressorimoottorien k\u00e4ytt\u00f6laitteet ja kaikki kaasunk\u00e4sittelyrakennuksen apupumppujen ja -puhaltimien k\u00e4ytt\u00f6laitteet kuuluvat vy\u00f6hykkeeseen 1. YB2 5,5\u201355 kW kompressorien apuk\u00e4ytt\u00f6laitteille.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-radius: 8px; padding: 14px;\">\n<div style=\"font-size: 14px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">Teollisuuden j\u00e4tevesien k\u00e4sittely<\/div>\n<p style=\"font-size: 13px; color: #555; margin: 0; line-height: 1.6;\">Teollisuuden j\u00e4tevedenk\u00e4sittely, jossa k\u00e4sitell\u00e4\u00e4n VOC-saastunutta j\u00e4tevett\u00e4 kemian-, elintarvike- tai l\u00e4\u00e4ketehtaista. Jos j\u00e4teveden syttyvien VOC-yhdisteiden pitoisuus k\u00e4sittelys\u00e4ili\u00f6n yl\u00e4osassa on yli 25% LEL, sovelletaan vy\u00f6hykett\u00e4 1 tai 2. YB2 IIB T4 kaikille moottoreille luokitelluilla vy\u00f6hykkeill\u00e4.<\/p>\n<\/div>\n<div style=\"background: #fff; border: 1px solid #d0dff0; border-radius: 8px; padding: 14px;\">\n<div style=\"font-size: 14px; font-weight: bold; color: #0a2240; margin: 0 0 5px;\">Seulontaseosten ja hiekan k\u00e4sittely<\/div>\n<p style=\"font-size: 13px; color: #555; margin: 0; line-height: 1.6;\">Seulakuljettimien k\u00e4ytt\u00f6laitteet, hiekanlajittelijan moottorit ja seulapuristimen k\u00e4ytt\u00f6laitteet laitoksen imualueella. Altistuvat tulevan j\u00e4teveden H\u2082S:lle; ei luokiteltu r\u00e4j\u00e4hdysvaaralliseksi, mutta sy\u00f6vytt\u00e4v\u00e4ss\u00e4 ymp\u00e4rist\u00f6ss\u00e4. YB2 0,55\u20133,0 kW imualueen k\u00e4ytt\u00f6laitteille vakio-Y2:n sijaan pidemm\u00e4n k\u00e4ytt\u00f6i\u00e4n takaamiseksi.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- FACTORY STRIP --><\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(180px,1fr)); gap: 12px; margin: 0 0 44px;\">\n<div>\n<p><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: 130px; object-fit: cover; border-radius: 8px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/about-factory-cnc-machining.webp\" alt=\"Korea Ever-Power YB2 valuraudan tarkkuusty\u00f6st\u00f6\" width=\"1345\" height=\"1170\" title=\"\"><\/p>\n<div style=\"font-size: 12px; color: #666; margin: 5px 0 0; text-align: center;\">Valuraudan ty\u00f6st\u00f6<\/div>\n<\/div>\n<div>\n<p><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: 130px; object-fit: cover; border-radius: 8px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/about-factory-qc-inspection.webp\" alt=\"Korea Ever-Power YB2 Ex d -j\u00e4tevesitesti\" width=\"1536\" height=\"1024\" title=\"\"><\/p>\n<div style=\"font-size: 12px; color: #666; margin: 5px 0 0; text-align: center;\">R\u00e4j\u00e4hdyskoe<\/div>\n<\/div>\n<div>\n<p><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: 130px; object-fit: cover; border-radius: 8px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/adv-certifications1.webp\" alt=\"Korea EverPower ATEX IECEx -j\u00e4tevesimoottori\" width=\"1448\" height=\"1086\" title=\"\"><\/p>\n<div style=\"font-size: 12px; color: #666; margin: 5px 0 0; text-align: center;\">ATEX- ja IECEx-standardit<\/div>\n<\/div>\n<div>\n<p><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: 130px; object-fit: cover; border-radius: 8px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/adv-global-shipping.webp\" alt=\"Korea Ever-Powerin maailmanlaajuinen j\u00e4tevesimoottorien vienti\" width=\"1448\" height=\"1086\" title=\"\"><\/p>\n<div style=\"font-size: 12px; color: #666; margin: 5px 0 0; text-align: center;\">Globaali vienti<\/div>\n<\/div>\n<\/div>\n<p><!-- FAQ --><\/p>\n<div id=\"faqA22\" style=\"margin: 0 0 44px;\">\n<h2 style=\"font-size: 26px; font-weight: 800; color: #0a2240; margin: 0 0 22px; padding-bottom: 10px; border-bottom: 2px solid #d0dff0;\">8. Usein kysytyt kysymykset<\/h2>\n<div style=\"display: flex; flex-direction: column; gap: 10px;\">\n<div style=\"border: 1px solid #d0dff0; border-radius: 8px; overflow: hidden;\">\n<div style=\"background: #0a2240; padding: 13px 18px;\">\n<div style=\"font-weight: bold; color: #fff; font-size: 14px;\">Tarvitseeko kunnallisen j\u00e4tevesilaitoksen ilmastusaltaan moottori r\u00e4j\u00e4hdyssuojatun sertifioinnin?<\/div>\n<\/div>\n<div style=\"padding: 16px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">Ei. Kunnallisen aktiivilietelaitoksen ilmastusallas ei ole luokiteltu vaaralliseksi alueeksi, koska ilmastettava j\u00e4tevesi on aerobista \u2013 syttyvien kaasujen merkitt\u00e4v\u00e4\u00e4 tuotantoa ei tapahdu r\u00e4j\u00e4hdysvaarallisen ilmakeh\u00e4n luokittelun edellytt\u00e4miss\u00e4 pitoisuuksissa. Ilmastusaltaiden pintailmastinten tai uppoilmastuspuhaltimien moottorit ovat tyypillisesti ulkok\u00e4ytt\u00f6\u00f6n tarkoitettuja Y2- tai YS-moottoreita, joiden luokitus on IP55. R\u00e4j\u00e4hdyssuojattuja moottoreita vaaditaan vain laitoksen anaerobisilla alueilla \u2013 p\u00e4\u00e4asiassa m\u00e4d\u00e4tt\u00e4m\u00f6rakennuksessa, kaasuvarastoissa ja kaikissa suljetuissa lietteenk\u00e4sittelytiloissa, joissa biokaasun kertyminen on mahdollista. Tutustu aina laitoksen vaarallisen alueen luokitusasiakirjaan, jonka p\u00e4tev\u00e4n henkil\u00f6n on laadittava kullekin j\u00e4tevedenpuhdistamolle, ennen kuin m\u00e4\u00e4rit\u00e4t moottorityypit millek\u00e4\u00e4n laitoksen alueelle.<\/p>\n<\/div>\n<\/div>\n<div style=\"border: 1px solid #d0dff0; border-radius: 8px; overflow: hidden;\">\n<div style=\"background: #0a2240; padding: 13px 18px;\">\n<div style=\"font-weight: bold; color: #fff; font-size: 14px;\">Mit\u00e4 huoltoa YB2-moottorit vaativat H\u2082S-j\u00e4tevesiymp\u00e4rist\u00f6iss\u00e4?<\/div>\n<\/div>\n<div style=\"padding: 16px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">Normaalin s\u00e4hk\u00f6tarkastuksen (laakerien kunto, eristysresistanssin mittaus, liit\u00e4nt\u00e4kotelon tarkastus) lis\u00e4ksi H\u2082S-j\u00e4tevesiymp\u00e4rist\u00f6iss\u00e4 k\u00e4ytett\u00e4ville YB2-moottoreille on teht\u00e4v\u00e4 vuosittainen ulkopinnoitteen silm\u00e4m\u00e4\u00e4r\u00e4inen tarkastus. Alueet, joissa maali on vaurioitunut iskun, hankauksen tai UV-s\u00e4teilyn seurauksena, tulee korjata merik\u00e4ytt\u00f6\u00f6n tarkoitetulla epoksipohjamaalilla ja polyuretaanipintamaalilla ennen kuin korroosio etenee valuraudan pintaan. Vy\u00f6hykkeiden 1 ja 2 moottoreille sovelletaan my\u00f6s IEC 60079-17 -standardin m\u00e4\u00e4r\u00e4aikaistarkastusvaatimuksia \u2013 niill\u00e4 varmistetaan, ett\u00e4 kaikki kiinnikkeet ovat paikallaan, liit\u00e4nt\u00e4kotelon kansi on tiivistetty oikein, Ex d -kaapelil\u00e4piviennit ovat tiukat ja moottorin runko ei ole rakenteellisesti sy\u00f6pynyt. S\u00e4ilyt\u00e4 valokuvat jokaisesta tarkastuksesta dokumentoidaksesi pinnoitteen kunnon kehityksen moottorin k\u00e4ytt\u00f6i\u00e4n aikana. Yli 50 ppm:n H\u2082S-alueilla tarkastusv\u00e4li\u00e4 on lyhennett\u00e4v\u00e4 6 kuukauteen ensimm\u00e4isten 3 k\u00e4ytt\u00f6vuoden aikana, jotta voidaan m\u00e4\u00e4ritt\u00e4\u00e4 todellinen korroosionopeus kyseisess\u00e4 kohdassa.<\/p>\n<\/div>\n<\/div>\n<div style=\"border: 1px solid #d0dff0; border-radius: 8px; overflow: hidden;\">\n<div style=\"background: #0a2240; padding: 13px 18px;\">\n<div style=\"font-weight: bold; color: #fff; font-size: 14px;\">Voinko k\u00e4ytt\u00e4\u00e4 taajuusmuuttajaa lietepumpun nopeuden s\u00e4\u00e4t\u00e4miseen j\u00e4tevesilaitoksen m\u00e4d\u00e4tt\u00e4m\u00f6alueella?<\/div>\n<\/div>\n<div style=\"padding: 16px 20px; background: #fff;\">\n<p style=\"font-size: 15px; color: #374151; margin: 0; line-height: 1.75;\">Kyll\u00e4, ja m\u00e4d\u00e4tt\u00e4m\u00f6n lietteen kierr\u00e4tyspumppujen VFD-nopeudens\u00e4\u00e4t\u00f6 s\u00e4\u00e4st\u00e4\u00e4 merkitt\u00e4v\u00e4sti energiaa ja parantaa m\u00e4d\u00e4tysprosessin ohjausta. VFD on asennettava vy\u00f6hyke 1 -luokitellun alueen ulkopuolelle \u2013 erilliseen MCC-huoneeseen tai paineistettuun Ex p -koteloon. VFD:n pumppuun yhdist\u00e4v\u00e4n moottorin on oltava YB2 Ex d IIB T4 -tyyppi\u00e4 taajuusmuuttajan sijainnista riippumatta. Moottorin puolelle on m\u00e4\u00e4ritett\u00e4v\u00e4 YB2, jossa on IC416-pakoj\u00e4\u00e4hdytyspuhaltimen k\u00e4ytt\u00f6 tavallisen IC411-akselille asennetun puhaltimen sijaan, jotta moottori voi tuottaa t\u00e4yden v\u00e4\u00e4nt\u00f6momentin alennetulla pumpun nopeudella ilman alhaisen nopeuden aiheuttamaa j\u00e4\u00e4hdytyshaittaa. T\u00e4m\u00e4 on erityisen t\u00e4rke\u00e4\u00e4 lietteen kierr\u00e4tyspumpuille, jotka toimivat suurimman osan m\u00e4d\u00e4tysjaksosta nimellisnopeudella 30\u201370%, jolloin IC411-j\u00e4\u00e4hdytys olisi riitt\u00e4m\u00e4t\u00f6nt\u00e4. Ota yhteytt\u00e4 Korea Ever-Poweriin saadaksesi lis\u00e4tietoja YB2 IC416 -lis\u00e4varusteen saatavuudesta ja pumpun tehoalueesi teknisist\u00e4 tiedoista.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- CTA --><\/p>\n<div style=\"position: relative; background: linear-gradient(135deg,#071828 0%,#0a2240 50%,#0e2e58 100%); border-radius: 12px; padding: 44px 40px; text-align: center; margin: 0 0 20px; overflow: hidden;\">\n<div style=\"position: absolute; top: 0; left: 0; right: 0; height: 3px; background: linear-gradient(90deg,#1e6fa8,#5bb3f0,#1e6fa8);\"><\/div>\n<p>&nbsp;<\/p>\n<div style=\"position: relative; z-index: 1;\">\n<div style=\"font-size: 11px; font-weight: bold; letter-spacing: 3px; text-transform: uppercase; color: #5bb3f0; margin: 0 0 12px;\">Korea Ever-Power \u00b7 YB2-sarja \u00b7 J\u00e4teveden k\u00e4sittelyyn tarkoitetut r\u00e4j\u00e4hdyssuojatut moottorit<\/div>\n<h2 style=\"font-size: clamp(18px,3vw,26px); font-weight: 900; color: #fff; margin: 0 0 12px;\">Tarvitsetko sertifioituja moottoreita j\u00e4tevedenpuhdistamollesi?<\/h2>\n<p style=\"color: #b0d4f0; margin: 0 0 24px; font-size: 15px; max-width: 520px; margin-left: auto; margin-right: auto; line-height: 1.65;\">Korea Ever-Power YB2: ATEX + IECEx Ex d IIB T4, IP55-valurauta, merik\u00e4ytt\u00f6\u00f6n tarkoitettu epoksipinnoite, 0,55\u2013200 kW. Kattaa biokaasuvy\u00f6hykkeet 1\/2 ja H\u2082S-lietealueet yhdell\u00e4 moottorilla.<\/p>\n<p><a style=\"display: inline-block; background: #1e6fa8; color: #fff; font-weight: 800; font-size: 14px; padding: 13px 32px; border-radius: 8px; text-decoration: none; margin: 0 6px 8px;\" href=\"https:\/\/industrialelectricmotor.net\/fi\/tuote-osasto\/explosion-proof-motors\/\">N\u00e4yt\u00e4 YB2-r\u00e4j\u00e4hdyssuojattu alue<\/a><\/p>\n<\/div>\n<\/div>\n<p style=\"font-size: 12px; color: #999; text-align: right; margin: 14px 0 0;\">Cxm:n muokkaama<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Korea Ever-Power \u00b7 YB2 Series \u00b7 Wastewater Treatment Drive Guide Explosion-Proof Motor for Wastewater Treatment Plant: Sludge Pump, Digester and Gas Zone Drive Guide Wastewater treatment plants handle multiple hazardous substances simultaneously: sewage sludge containing hydrogen sulphide (H\u2082S) released during digestion, biogas (primarily methane) generated in anaerobic digesters, and industrial effluent containing volatile organic solvents. [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[28],"tags":[],"class_list":["post-202","post","type-post","status-publish","format-standard","hentry","category-industrial-electric-motor"],"_links":{"self":[{"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/posts\/202","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/comments?post=202"}],"version-history":[{"count":1,"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/posts\/202\/revisions"}],"predecessor-version":[{"id":205,"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/posts\/202\/revisions\/205"}],"wp:attachment":[{"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/media?parent=202"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/categories?post=202"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/industrialelectricmotor.net\/fi\/wp-json\/wp\/v2\/tags?post=202"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}