YB2 Series 4-Pole Explosion-Proof Motor
Four-pole flameproof squirrel-cage induction motor certified Ex d IIB T4 for Zone 1 and Zone 2 hazardous areas. Running at approximately 1460 rpm on 380 V 50 Hz, the 4-pole YB2 is the most widely specified explosion-proof motor across the full range — covering the majority of hazardous area pump, compressor, agitator, and conveyor drives where moderate speed and high torque are both required.
Zone 1 / Zone 2
Speed: ~1460 rpm (4P)
Power: 0.55 – 200 kW
Protection: IP55
Insulation: Class F


The Most Widely Used Explosion-Proof Motor in the YB2 Range
The 4-pole YB2 is the default specification for hazardous area motor installations. At 1460 rpm, it matches the operating speed of the largest range of centrifugal pump impellers, compressor stages, and fan rotors designed for direct coupling to 50 Hz induction motors. This eliminates the need for belt or chain drives between motor and driven equipment, which would themselves present additional potential ignition sources in a classified area and require their own hazardous-area safety assessment.
The flameproof enclosure design follows IEC 60079-1 exactly as for the 2-pole variant, with all flame path joints machined to certified dimensions. The 4-pole winding produces twice the shaft torque of the 2-pole motor at the same power rating, giving the 4-pole motor a significant advantage in direct-coupled agitator and mixer applications where high starting torque under viscous load is required alongside the moderate operating speed.
The power range extends from 0.55 kW (frame 71) through 200 kW (frame 315M), the widest range in the YB2 series. All units carry IP55 protection, Class F insulation, and both CE and Ex marks. The terminal box accommodates flameproof cable glands for the cable sizes appropriate to each frame, with sufficient internal volume for safe termination of armoured cables without deforming the cable gland assembly.
View the full explosion-proof range on the Explosion-Proof Motors page, or compare with the Three-Phase Induction Motors for non-hazardous area equivalents.
YB2 4-Pole Model Specifications — Ex d IIB T4
All models: 4-pole, ~1460 rpm, 380 V 50 Hz, IP55, Class F insulation, Ex d IIB T4, Zone 1 and Zone 2.
| Model | Frame | kW | Full-Load A | rpm | η % | cosφ | Tst/Tn | Ist/In | kg |
|---|---|---|---|---|---|---|---|---|---|
| YB2-71M-4 | 71M | 0.55 | 1.68 | 1380 | 69.5 | 0.75 | 2.2 | 5.5 | 14 |
| YB2-80M1-4 | 80M | 0.75 | 2.22 | 1390 | 72.5 | 0.76 | 2.2 | 6.0 | 22 |
| YB2-80M2-4 | 80M | 1.1 | 3.14 | 1400 | 75.5 | 0.77 | 2.2 | 6.0 | 24 |
| YB2-90S-4 | 90S | 1.5 | 4.14 | 1410 | 77.5 | 0.78 | 2.2 | 6.0 | 30 |
| YB2-90L-4 | 90L | 2.2 | 5.78 | 1420 | 80.0 | 0.79 | 2.2 | 6.5 | 38 |
| YB2-100L1-4 | 100L | 3.0 | 7.50 | 1430 | 82.0 | 0.80 | 2.2 | 6.5 | 48 |
| YB2-100L2-4 | 100L | 4.0 | 9.80 | 1440 | 83.5 | 0.80 | 2.2 | 6.5 | 54 |
| YB2-112M-4 | 112M | 5.5 | 12.80 | 1445 | 85.0 | 0.82 | 2.2 | 7.0 | 72 |
| YB2-132S-4 | 132S | 7.5 | 16.90 | 1448 | 86.5 | 0.83 | 2.2 | 7.0 | 92 |
| YB2-132M-4 | 132M | 11 | 24.20 | 1450 | 87.5 | 0.83 | 2.2 | 7.0 | 120 |
| YB2-160M-4 | 160M | 15 | 32.00 | 1455 | 88.5 | 0.84 | 2.0 | 7.0 | 160 |
| YB2-160L-4 | 160L | 18.5 | 38.80 | 1458 | 89.5 | 0.84 | 2.0 | 7.0 | 188 |
| YB2-180M-4 | 180M | 22 | 45.40 | 1460 | 90.5 | 0.85 | 2.0 | 7.0 | 235 |
| YB2-180L-4 | 180L | 30 | 60.50 | 1460 | 91.0 | 0.86 | 2.0 | 7.0 | 282 |
| YB2-200L-4 | 200L | 37 | 73.50 | 1462 | 92.0 | 0.86 | 2.0 | 7.0 | 345 |
| YB2-225S-4 | 225S | 45 | 88.00 | 1464 | 92.5 | 0.87 | 2.0 | 7.0 | 410 |
| YB2-225M-4 | 225M | 55 | 106.00 | 1465 | 93.0 | 0.87 | 2.0 | 7.0 | 480 |
| YB2-250M-4 | 250M | 75 | 143.00 | 1468 | 93.5 | 0.88 | 2.0 | 7.0 | 605 |
| YB2-280S-4 | 280S | 90 | 170.00 | 1470 | 94.0 | 0.88 | 2.0 | 7.0 | 720 |
| YB2-315S-4 | 315S | 132 | 248.00 | 1472 | 94.5 | 0.89 | 2.0 | 7.0 | 950 |
| YB2-315M-4 | 315M | 200 | 372.00 | 1475 | 95.0 | 0.89 | 2.0 | 7.0 | 1180 |
Operating Conditions
| Ambient temperature | −20 °C to +40 °C |
| Altitude | ≤ 1000 m ASL |
| Supply voltage | 380 V ± 5% |
| Frequency | 50 Hz ± 1% |
| Mounting | IMB3 / IMB5 / IMB35 |
| Protection | IP55 |
| Insulation class | Class F |
| Temperature rise | Class B limit |
| Max surface temp | 135 °C (T4) |
Hazardous Area Certification
| Protection method | Ex d (flameproof) |
| Gas group | IIB |
| Temperature class | T4 (135 °C max) |
| Zone suitability | Zone 1, Zone 2 |
| Ex standard | IEC 60079-1 |
| Motor standard | IEC 60034 |
| Quality management | ISO 9001 |
| Marking | CE / Ex |
Typical Applications for YB2 4-Pole Explosion-Proof Motors
API Process Pumps
API 610 and API 676 process pumps for refinery and chemical plant duties are designed for direct coupling to 4-pole motors at 1460 rpm. The YB2-4 is the standard motor specification for these pumps in classified Zone 1 process areas across the majority of oil and gas engineering standards.
|
Gas Compressor Drives
Screw and reciprocating compressors in natural gas gathering stations, LPG terminals, and biogas upgrading plants use 4-pole Ex d motors as the primary drive because most compressor designs are optimised for input speeds in the 1200 to 1500 rpm range matching the 4-pole motor.
|
Pharmaceutical Reactors
Top-entry agitators on classified pharmaceutical synthesis reactors use 4-pole Ex d motors for the combination of moderate impeller speed, high starting torque for viscous batches, and Ex d flameproof protection required by ATEX zone classification of solvent-handling reaction areas.
|
|
⛽
Zone 1 Conveyor Drives
Screw conveyors and belt conveyors inside chemical storage warehouses, flour mills, and grain silos classified as Zone 1 or Zone 2 for combustible dust and flammable vapour use 4-pole Ex d IIB motors as the standard drive motor throughout the classified area boundary.
|
🏭
Offshore Platform Equipment
Seawater lift pumps, firewater pumps, and injection water pumps on oil and gas production platforms operate in Zone 2 classified areas and require Ex d IIB T4 motors that also meet offshore environmental requirements for salt air, vibration, and corrosion resistance.
|
🐈
Solvent Recovery Systems
Distillation column reboiler pumps, reflux pumps, and solvent condensate pumps in solvent recovery and recycling plants handle flammable liquids at elevated temperatures, requiring Ex d IIB T4 motors throughout the classified area surrounding each distillation column.
|
Why the 4-Pole Configuration Dominates Hazardous Area Motor Specifications
Equipment Speed Compatibility
The majority of centrifugal pumps, fans, compressors, and agitators used in the process industries are designed with specific-speed characteristics optimised for direct coupling to 4-pole motors at 1440 to 1480 rpm. Pump hydraulic design, impeller geometry, and shaft seal assembly dimensions are all coordinated around this speed in IEC-aligned markets. Specifying a 4-pole Ex d motor therefore eliminates the need for a belt or gear drive between motor and driven equipment, which would itself require hazardous area assessment and add maintenance complexity inside the classified zone.
Torque Advantage Over 2-Pole for Agitators
A 4-pole motor produces twice the shaft torque of a 2-pole motor at the same power rating, because torque equals power divided by angular velocity. For top-entry agitators starting under full viscous load, this additional torque margin allows reliable cold-batch starting without star-delta starting or soft-starter intervention. In classified areas, minimising auxiliary starting equipment inside the zone boundary reduces both the total number of certified components required and the inspection load during periodic maintenance shutdowns.
Thermal Management at IP55
Ex d motors operate at IP55 as standard, which means the cooling fin surface must transfer all winding heat to the ambient air without any ingress of external air through the motor enclosure. The 4-pole motor at 1460 rpm delivers full rated cooling fan airflow and fin surface velocity, maintaining the motor within T4 surface temperature limits at full rated load. This self-contained cooling arrangement is essential in hazardous areas where external forced cooling blowers would require their own Ex certification and separate power supply.
Frequently Asked Questions — YB2 Series 4-Pole Explosion-Proof Motor
Request a Quote for YB2 4-Pole Explosion-Proof Motors
Specify power (kW), hazardous area zone, gas group, any national certification requirements, and quantity. Learn about our factory on the About Us page.
追加情報