{"id":143,"date":"2026-07-08T08:39:53","date_gmt":"2026-07-08T08:39:53","guid":{"rendered":"https:\/\/industrialelectricmotor.net\/?post_type=product&#038;p=143"},"modified":"2026-07-08T08:39:54","modified_gmt":"2026-07-08T08:39:54","slug":"yb2-series-8-pole-explosion-proof-motor","status":"publish","type":"product","link":"https:\/\/industrialelectricmotor.net\/ko\/product\/yb2-series-8-pole-explosion-proof-motor\/","title":{"rendered":"YB2 Series 8-Pole Explosion-Proof Motor"},"content":{"rendered":"<div style=\"font-family: Arial,Helvetica,sans-serif; font-size: 16px; line-height: 1.8; color: #333; max-width: 100%; margin: 0 auto;\">\n<div style=\"display: flex; flex-wrap: wrap; gap: 12px; margin: 0 0 40px;\">\n<div style=\"flex: 1 1 150px; background: #1A3A6B; color: #fff; padding: 12px 16px; border-radius: 6px; text-align: center; font-size: 13px; font-weight: 600;\">Ex d Flameproof<\/div>\n<div style=\"flex: 1 1 150px; background: #1A3A6B; color: #fff; padding: 12px 16px; border-radius: 6px; text-align: center; font-size: 13px; font-weight: 600;\">Group IIB T4<\/div>\n<div style=\"flex: 1 1 150px; background: #1A3A6B; color: #fff; padding: 12px 16px; border-radius: 6px; text-align: center; font-size: 13px; font-weight: 600;\">8-Pole 720 rpm<\/div>\n<div style=\"flex: 1 1 150px; background: #1A3A6B; color: #fff; padding: 12px 16px; border-radius: 6px; text-align: center; font-size: 13px; font-weight: 600;\">Maximum Torque<\/div>\n<div style=\"flex: 1 1 150px; background: #1A3A6B; color: #fff; padding: 12px 16px; border-radius: 6px; text-align: center; font-size: 13px; font-weight: 600;\">IEC 60079-1<\/div>\n<div style=\"flex: 1 1 150px; background: #1A3A6B; color: #fff; padding: 12px 16px; border-radius: 6px; text-align: center; font-size: 13px; font-weight: 600;\">ISO 9001 Certified<\/div>\n<\/div>\n<div style=\"display: flex; flex-wrap: wrap; gap: 36px; margin: 0 0 50px; align-items: flex-start;\">\n<div style=\"flex: 1 1 340px; min-width: 260px;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 10px; box-shadow: 0 4px 20px rgba(0,0,0,0.08);\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/cat-explosion-proof-motor.webp\" alt=\"YB2 Series 8-Pole Explosion-Proof Motor Ex d IIB T4 Korea Ever-Power\" width=\"600\" height=\"600\" title=\"\"><br \/>\n<img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 10px; box-shadow: 0 4px 20px rgba(0,0,0,0.08); margin-top: 16px;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/three-phase-motor-installation-method.webp\" alt=\"YB2 Motor IEC Mounting Methods IMB3 IMB5 IMB35\" width=\"1448\" height=\"1086\" title=\"\"><\/div>\n<div style=\"flex: 1 1 380px; min-width: 280px;\">\n<h2 style=\"font-size: 24px; font-weight: bold; color: #1a3a6b; margin: 0 0 16px; line-height: 1.3;\">Highest Torque Density in the YB2 Ex d Range for Direct-Coupled Hazardous Area Drives<\/h2>\n<p style=\"margin: 0 0 14px;\">The 8-pole YB2 runs at approximately 720 rpm, delivering four times the shaft torque of a 2-pole motor at the same power rating. This extreme torque density enables direct coupling to driven equipment at very low shaft speeds without any intermediate reduction gearing inside the classified zone. For large agitators on chemical storage tanks and crude oil desalters, this means the motor can couple directly to the impeller shaft, and the motor frame can be bolted to the vessel top nozzle flange \u2014 the entire drive consisting of a single certified component plus the coupling.<\/p>\n<p style=\"margin: 0 0 14px;\">The flameproof enclosure is engineered to the same IEC 60079-1 flame path standards as the rest of the YB2 range. At 720 rpm, all heat-generating mechanical phenomena \u2014 bearing friction, windage, shaft seal slip \u2014 are at their lowest in the range, giving the 8-pole motor the greatest thermal margin below the T4 surface temperature ceiling of 135 \u00b0C. This additional margin is valuable in outdoor installations in hot climates where ambient temperatures approach 40 \u00b0C, and where solar radiation on the motor casing can add 5 to 10 K to the effective ambient.<\/p>\n<p style=\"margin: 0 0 14px;\">Frame sizes cover 100L through 280M (1.5 kW to 90 kW). Cast-iron construction throughout ensures the wall thickness needed for flame path geometry is maintained across all frame sizes. IP55 protection, Class F insulation with Class B temperature-rise limits, and CE plus Ex marking are standard on all models.<\/p>\n<p style=\"margin: 0 0 0;\">View the complete hazardous area motor range on the <a style=\"color: #1a3a6b; font-weight: 600;\" href=\"https:\/\/industrialelectricmotor.net\/ko\/product-category\/explosion-proof-motors\/\">Explosion-Proof Motors<\/a> page, or see standard motors at <a style=\"color: #1a3a6b; font-weight: 600;\" href=\"https:\/\/industrialelectricmotor.net\/ko\/product-category\/three-phase-induction-motors\/\">Three-Phase Induction Motors<\/a>.<\/p>\n<\/div>\n<\/div>\n<h2 style=\"font-size: 22px; font-weight: bold; color: #1a3a6b; margin: 0 0 20px; border-left: 4px solid #1A3A6B; padding-left: 14px;\">YB2 8-Pole Model Specifications \u2014 Ex d IIB T4<\/h2>\n<p style=\"margin: 0 0 20px; color: #555;\">All models: 8-pole, ~720 rpm, 380 V 50 Hz, IP55, Class F insulation, Ex d IIB T4, Zone 1 and Zone 2.<\/p>\n<div style=\"overflow-x: auto; margin: 0 0 50px;\">\n<table style=\"width: 100%; border-collapse: collapse; font-size: 14px; min-width: 780px;\">\n<thead>\n<tr style=\"background: #1A3A6B; color: #fff;\">\n<th style=\"padding: 10px 12px; text-align: left; white-space: nowrap;\">Model<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">Frame<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">kW<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">Full-Load A<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">rpm<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">\u03b7 %<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">cos\u03c6<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">Tst\/Tn<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">Ist\/In<\/th>\n<th style=\"padding: 10px 12px; text-align: center;\">kg<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #f0f4ff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-100L1-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">100L<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">1.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.50<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">680<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">62.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.62<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">55<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-100L2-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">100L<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.2<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">7.70<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">690<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">65.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.63<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">62<\/td>\n<\/tr>\n<tr style=\"background: #f0f4ff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-112M-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">112M<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">3.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">10.00<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">700<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">68.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.64<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">80<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-132S-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">132S<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">4.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">13.00<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">706<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">71.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.65<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">102<\/td>\n<\/tr>\n<tr style=\"background: #f0f4ff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-132M-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">132M<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">17.20<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">710<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">74.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.66<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">130<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-160M-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">160M<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">7.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">23.00<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">715<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">77.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.67<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">182<\/td>\n<\/tr>\n<tr style=\"background: #f0f4ff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-160L-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">160L<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">11<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">32.80<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">718<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">79.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.68<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">218<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-180L-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">180L<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">15<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">43.50<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">720<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">81.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.69<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">272<\/td>\n<\/tr>\n<tr style=\"background: #f0f4ff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-200L-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">200L<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">18.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">52.50<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">722<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">83.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.70<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">2.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">348<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-225S-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">225S<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">22<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">61.20<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">724<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">84.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.71<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">1.8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">428<\/td>\n<\/tr>\n<tr style=\"background: #f0f4ff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-225M-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">225M<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">30<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">82.00<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">726<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">86.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.71<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">1.8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">5.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">502<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-250M-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">250M<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">45<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">120.00<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">728<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">87.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.72<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">1.8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">6.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">628<\/td>\n<\/tr>\n<tr style=\"background: #f0f4ff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-280S-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">280S<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">55<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">144.00<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">730<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">88.5<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.73<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">1.8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">6.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">752<\/td>\n<\/tr>\n<tr style=\"background: #fff;\">\n<td style=\"padding: 9px 12px; font-weight: 600; white-space: nowrap;\">YB2-280M-8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">280M<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">90<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">233.00<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">732<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">90.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">0.74<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">1.8<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">6.0<\/td>\n<td style=\"padding: 9px 12px; text-align: center;\">920<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div style=\"display: flex; flex-wrap: wrap; gap: 24px; margin: 0 0 50px;\">\n<div style=\"flex: 1 1 300px; background: #f8f9ff; border-radius: 10px; padding: 28px 24px; border: 1px solid #dde3f0;\">\n<h3 style=\"font-size: 17px; font-weight: bold; color: #1a3a6b; margin: 0 0 16px;\">Operating Conditions<\/h3>\n<table style=\"width: 100%; border-collapse: collapse; font-size: 14px;\">\n<tbody>\n<tr>\n<td style=\"padding: 6px 0; color: #555; width: 55%;\">Ambient temperature<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">\u221220 \u00b0C to +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Altitude<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">\u2264 1000 m ASL<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Supply voltage<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">380 V \u00b1 5%<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Frequency<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">50 Hz \u00b1 1%<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Mounting<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">IMB3 \/ IMB5 \/ IMB35<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Protection<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">IP55<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Insulation class<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">Class F<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Temperature rise<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">Class B limit<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Max surface temp<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">135 \u00b0C (T4)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div style=\"flex: 1 1 300px; background: #f8f9ff; border-radius: 10px; padding: 28px 24px; border: 1px solid #dde3f0;\">\n<h3 style=\"font-size: 17px; font-weight: bold; color: #1a3a6b; margin: 0 0 16px;\">Hazardous Area Certification<\/h3>\n<table style=\"width: 100%; border-collapse: collapse; font-size: 14px;\">\n<tbody>\n<tr>\n<td style=\"padding: 6px 0; color: #555; width: 55%;\">Protection method<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">Ex d (flameproof)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Gas group<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">IIB<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Temperature class<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">T4 (135 \u00b0C max)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Zone suitability<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">Zone 1, Zone 2<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Ex standard<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">IEC 60079-1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Motor standard<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">IEC 60034<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Quality management<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">ISO 9001<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 6px 0; color: #555;\">Marking<\/td>\n<td style=\"padding: 6px 0; font-weight: 600;\">CE \/ Ex<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 style=\"font-size: 22px; font-weight: bold; color: #1a3a6b; margin: 0 0 20px; border-left: 4px solid #1A3A6B; padding-left: 14px;\">Typical Applications for YB2 8-Pole Explosion-Proof Motors<\/h2>\n<table style=\"width: 100%; border-collapse: collapse; margin: 0 0 16px;\">\n<tbody>\n<tr>\n<td style=\"width: 33.3%; padding: 0 12px 0 0; vertical-align: top;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 8px; margin: 0 0 12px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/app-chemical-plant.webp\" alt=\"YB2 8-Pole Motor Classified Zone Agitator Application\" width=\"800\" height=\"500\" title=\"\"><\/p>\n<div style=\"background: #f0f4ff; border-radius: 10px; padding: 18px 16px;\">\n<div style=\"font-weight: bold; color: #1a3a6b; margin: 0 0 8px; font-size: 15px;\">Crude Oil Desalter Agitators<\/div>\n<div style=\"font-size: 13px; color: #555; line-height: 1.6;\">Horizontal crude oil desalter vessels use large-diameter impeller agitators running at 60 to 120 rpm. The 8-pole YB2 at 720 rpm through a small-ratio gearbox or direct coupling achieves this speed with maximum torque, while keeping the entire drive assembly inside the Zone 1 classified crude unit area as simple as possible.<\/div>\n<\/div>\n<\/td>\n<td style=\"width: 33.3%; padding: 0 6px; vertical-align: top;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 8px; margin: 0 0 12px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/app-mining-conveyor.webp\" alt=\"YB2 8-Pole Motor Classified Conveyor Application\" width=\"800\" height=\"500\" title=\"\"><\/p>\n<div style=\"background: #f0f4ff; border-radius: 10px; padding: 18px 16px;\">\n<div style=\"font-weight: bold; color: #1a3a6b; margin: 0 0 8px; font-size: 15px;\">Classified Area Conveyors<\/div>\n<div style=\"font-size: 13px; color: #555; line-height: 1.6;\">Screw conveyors moving powdered chemicals and grain inside Zone 1 classified storage areas use 8-pole Ex d IIB motors for their high torque at low speed, avoiding jamming on startup under settled material while keeping drive equipment inside the zone to the minimum number of certified components.<\/div>\n<\/div>\n<\/td>\n<td style=\"width: 33.3%; padding: 0 0 0 12px; vertical-align: top;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto; border-radius: 8px; margin: 0 0 12px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/app-hvac-pump-room.webp\" alt=\"YB2 8-Pole Motor Classified Fan Application\" width=\"800\" height=\"500\" title=\"\"><\/p>\n<div style=\"background: #f0f4ff; border-radius: 10px; padding: 18px 16px;\">\n<div style=\"font-weight: bold; color: #1a3a6b; margin: 0 0 8px; font-size: 15px;\">Very Large Diameter Fans<\/div>\n<div style=\"font-size: 13px; color: #555; line-height: 1.6;\">Cooling tower fans and large-diameter axial flow fans in classified areas use the 8-pole motor at 720 rpm for direct drive of fan hubs at the low blade tip speed required for efficient large-diameter axial flow designs, while maintaining Ex d flameproof protection throughout.<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100%; border-collapse: collapse; margin: 0 0 50px;\">\n<tbody>\n<tr>\n<td style=\"width: 33.3%; padding: 8px 12px 0 0; vertical-align: top;\">\n<div style=\"background: #f0f4ff; border-radius: 10px; padding: 18px 16px;\">\n<div style=\"font-size: 28px; margin: 0 0 8px;\">\u26fd<\/div>\n<div style=\"font-weight: bold; color: #1a3a6b; margin: 0 0 8px; font-size: 15px;\">LNG Tank Agitators<\/div>\n<div style=\"font-size: 13px; color: #555; line-height: 1.6;\">LNG stratification prevention agitators in classified cryogenic storage areas require Ex d motors rated for low ambient temperatures as well as flammable atmosphere protection. The 8-pole YB2 with low-temperature rating provides direct-shaft agitation of LNG stratification without internal zone gearboxes.<\/div>\n<\/div>\n<\/td>\n<td style=\"width: 33.3%; padding: 8px 6px 0; vertical-align: top;\">\n<div style=\"background: #f0f4ff; border-radius: 10px; padding: 18px 16px;\">\n<div style=\"font-size: 28px; margin: 0 0 8px;\">\ud83d\udd25<\/div>\n<div style=\"font-weight: bold; color: #1a3a6b; margin: 0 0 8px; font-size: 15px;\">Reactor Vessel Drives<\/div>\n<div style=\"font-size: 13px; color: #555; line-height: 1.6;\">Stirred-tank reactors for polymer and specialty chemical synthesis operating in classified areas use 8-pole Ex d motors for their ability to start and sustain rotation of large-diameter high-viscosity batch loads without excessive starting current at moderate supply capacity.<\/div>\n<\/div>\n<\/td>\n<td style=\"width: 33.3%; padding: 8px 0 0 12px; vertical-align: top;\">\n<div style=\"background: #f0f4ff; border-radius: 10px; padding: 18px 16px;\">\n<div style=\"font-size: 28px; margin: 0 0 8px;\">\ud83d\udea2<\/div>\n<div style=\"font-weight: bold; color: #1a3a6b; margin: 0 0 8px; font-size: 15px;\">Thickener and Filter Drives<\/div>\n<div style=\"font-size: 13px; color: #555; line-height: 1.6;\">Rake drives on thickeners and vacuum filter drum drives in classified mineral processing areas use 8-pole Ex d motors for the high torque needed to move rake arms through settled slurry, combined with the flameproof protection required by the process chemicals present in the area.<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div style=\"background: #f8f9ff; border-radius: 12px; padding: 36px 32px; margin: 0 0 50px; border: 1px solid #dde3f0;\">\n<h2 style=\"font-size: 22px; font-weight: bold; color: #1a3a6b; margin: 0 0 20px;\">Selecting Between 6-Pole and 8-Pole Ex d Motors for Classified Area Agitators<\/h2>\n<div style=\"display: flex; flex-wrap: wrap; gap: 28px;\">\n<div style=\"flex: 1 1 280px;\">\n<h3 style=\"font-size: 16px; font-weight: bold; color: #1a3a6b; margin: 0 0 10px;\">Required Impeller Speed<\/h3>\n<p style=\"font-size: 14px; color: #555; margin: 0; line-height: 1.7;\">The primary factor in choosing between 6-pole (960 rpm) and 8-pole (720 rpm) for an agitator is the impeller tip speed required by the mixing duty. High-shear duties (emulsification, gas dispersion) typically require 200 to 500 m\/min tip speed, which with a 600 mm diameter impeller requires 100 to 265 rpm \u2014 achievable with a single-stage gearbox from either pole count. Low-shear duties (bulk blending, solids suspension) require 30 to 100 rpm tip speed, which favours the 8-pole motor with lower ratio reduction because the starting torque requirement at these low impeller speeds is highest and benefits from the maximum torque of the 8-pole configuration.<\/p>\n<\/div>\n<div style=\"flex: 1 1 280px;\">\n<h3 style=\"font-size: 16px; font-weight: bold; color: #1a3a6b; margin: 0 0 10px;\">T4 Compliance in Hot Climates<\/h3>\n<p style=\"font-size: 14px; color: #555; margin: 0; line-height: 1.7;\">In outdoor classified area installations in the Middle East, Southeast Asia, and equatorial Africa where ambient temperatures regularly reach 40 \u00b0C and solar radiation can add 10 to 15 K to the effective surface temperature, the thermal margin provided by the 8-pole motor at 720 rpm versus the 6-pole motor at 960 rpm can be decisive. The lower windage losses and bearing friction of the 8-pole motor reduce the motor surface temperature by an estimated 3 to 5 K at the same rated load and ambient, providing measurable additional compliance margin below the T4 ceiling in the most demanding installation environments.<\/p>\n<\/div>\n<div style=\"flex: 1 1 280px;\">\n<h3 style=\"font-size: 16px; font-weight: bold; color: #1a3a6b; margin: 0 0 10px;\">Gearbox Elimination Inside Zone<\/h3>\n<p style=\"font-size: 14px; color: #555; margin: 0; line-height: 1.7;\">For agitator duties requiring 50 to 150 rpm output, the 8-pole motor at 720 rpm requires a gearbox ratio of only 5:1 to 15:1. Single-stage helical or worm gearboxes can cover this range, whereas the same duty from a 4-pole motor at 1460 rpm would require a 10:1 to 30:1 ratio, typically necessitating a two-stage gearbox. In Zone 1 areas where every additional component inside the boundary adds to the maintenance burden and the number of items requiring periodic inspection under IEC 60079-17, eliminating a gearbox stage has real safety management and cost value over the motor service life.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"margin: 0 0 50px;\">\n<div style=\"display: flex; flex-wrap: wrap; gap: 16px; align-items: stretch;\">\n<div style=\"flex: 1 1 220px; min-width: 180px;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: 180px; object-fit: cover; border-radius: 8px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/about-factory-rotor-production.webp\" alt=\"Korea Ever-Power Rotor Production\" width=\"1402\" height=\"1122\" title=\"\"><\/p>\n<div style=\"padding: 12px 0 0; font-size: 13px; color: #555; text-align: center;\">Rotor Production Line<\/div>\n<\/div>\n<div style=\"flex: 1 1 220px; min-width: 180px;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: 180px; object-fit: cover; border-radius: 8px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/about-factory-cnc-machining.webp\" alt=\"Korea Ever-Power Precision Flame-Path Machining\" width=\"1345\" height=\"1170\" title=\"\"><\/p>\n<div style=\"padding: 12px 0 0; font-size: 13px; color: #555; text-align: center;\">Precision Flame-Path Machining<\/div>\n<\/div>\n<div style=\"flex: 1 1 220px; min-width: 180px;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: 180px; object-fit: cover; border-radius: 8px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/about-factory-qc-inspection.webp\" alt=\"Korea Ever-Power QC Inspection\" width=\"1536\" height=\"1024\" title=\"\"><\/p>\n<div style=\"padding: 12px 0 0; font-size: 13px; color: #555; text-align: center;\">QC and Certification Inspection<\/div>\n<\/div>\n<div style=\"flex: 1 1 220px; min-width: 180px;\"><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: 180px; object-fit: cover; border-radius: 8px; display: block;\" src=\"https:\/\/industrialelectricmotor.net\/wp-content\/uploads\/2026\/07\/contact-global-customers-map.webp\" alt=\"Korea Ever-Power Global Export Network\" width=\"1672\" height=\"941\" title=\"\"><\/p>\n<div style=\"padding: 12px 0 0; font-size: 13px; color: #555; text-align: center;\">Global Customer Network<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2 style=\"font-size: 22px; font-weight: bold; color: #1a3a6b; margin: 0 0 24px; border-left: 4px solid #1A3A6B; padding-left: 14px;\">Frequently Asked Questions \u2014 YB2 Series 8-Pole Explosion-Proof Motor<\/h2>\n<div style=\"margin: 0 0 50px;\">\n<div style=\"border: 1px solid #dde3f0; border-radius: 8px; margin: 0 0 12px; overflow: hidden;\">\n<div style=\"background: #f0f4ff; padding: 16px 20px; font-weight: bold; color: #1a3a6b; font-size: 15px;\">Why does the 8-pole YB2 power range stop at 90 kW when the 4-pole range reaches 200 kW?<\/div>\n<div style=\"padding: 16px 20px; font-size: 14px; color: #444; line-height: 1.7;\">Above 90 kW at 720 rpm, the shaft torque becomes very large (approximately 1,200 N\u00b7m for a 90 kW 8-pole motor), requiring a shaft diameter and bearing arrangement that pushes the motor into a larger frame series than is covered by the standard IEC 72-1 table for frame 280M. Very large slow-speed motors above 90 kW in classified areas are typically specified as custom designs with separate engineering and Ex certification assessment. Korea Ever-Power can discuss custom Ex d slow-speed motor requirements above 90 kW on a project-specific basis. For most standard agitator and conveyor applications, the 90 kW ceiling of the YB2-8 range covers the large majority of process equipment in the relevant duty range.<\/div>\n<\/div>\n<div style=\"border: 1px solid #dde3f0; border-radius: 8px; margin: 0 0 12px; overflow: hidden;\">\n<div style=\"background: #f0f4ff; padding: 16px 20px; font-weight: bold; color: #1a3a6b; font-size: 15px;\">Is the power factor penalty of the 8-pole motor significant in hazardous area installations?<\/div>\n<div style=\"padding: 16px 20px; font-size: 14px; color: #444; line-height: 1.7;\">Yes. The 8-pole motor has a typical full-load power factor of 0.62 to 0.74, which is significantly lower than the 0.84 to 0.89 of a 4-pole motor at the same frame size. In classified area installations where hazardous area regulations restrict the installation of capacitor banks inside the zone (capacitors can generate sparks on connection and disconnection), power factor correction must be applied outside the zone boundary. This means the supply cable to the classified area must be sized for the higher apparent current of the uncorrected 8-pole motor, which increases cable cost on long runs. For supply cable runs above 50 metres, the cable sizing cost difference between an 8-pole and a 4-pole motor at the same output power should be included in the total system cost comparison.<\/div>\n<\/div>\n<div style=\"border: 1px solid #dde3f0; border-radius: 8px; margin: 0 0 12px; overflow: hidden;\">\n<div style=\"background: #f0f4ff; padding: 16px 20px; font-weight: bold; color: #1a3a6b; font-size: 15px;\">What shaft extension options are available for direct impeller mounting?<\/div>\n<div style=\"padding: 16px 20px; font-size: 14px; color: #444; line-height: 1.7;\">The standard IEC 72-1 shaft extension dimensions are supplied as default. For direct impeller mounting applications (where the impeller is mounted directly on the motor shaft extension without a separate agitator shaft), Korea Ever-Power can supply extended and reinforced shaft variants with larger diameter and longer extension to accommodate impeller hub mounting, key and keyway, and end-plate retention. The shaft extension must be specified to carry the combined bending moment from the impeller weight and the hydraulic forces at the impeller face. Korea Ever-Power application engineers can assist with shaft sizing calculations when the impeller geometry and process conditions are provided.<\/div>\n<\/div>\n<div style=\"border: 1px solid #dde3f0; border-radius: 8px; margin: 0 0 12px; overflow: hidden;\">\n<div style=\"background: #f0f4ff; padding: 16px 20px; font-weight: bold; color: #1a3a6b; font-size: 15px;\">What starting method is recommended for the 8-pole YB2 starting under full load?<\/div>\n<div style=\"padding: 16px 20px; font-size: 14px; color: #444; line-height: 1.7;\">For frame sizes up to 160L, direct-on-line starting is the standard method. The lower starting current multiplier (Ist\/In of 5.0 to 6.0) of the 8-pole motor relative to 2-pole and 4-pole motors of the same power means that direct starting current is manageable from most industrial supply systems. For frame sizes 180L and above, star-delta starting or a thyristor soft starter located outside the Zone 1 boundary reduces supply disturbance and mechanical shock on impeller and gearbox at start. The soft starter must be bypassed after run-up to avoid continuous thyristor losses, and the bypass contactor must be outside the zone boundary or Ex certified if located inside.<\/div>\n<\/div>\n<div style=\"border: 1px solid #dde3f0; border-radius: 8px; margin: 0 0 12px; overflow: hidden;\">\n<div style=\"background: #f0f4ff; padding: 16px 20px; font-weight: bold; color: #1a3a6b; font-size: 15px;\">Can the YB2 8-pole be fitted with an encoder for speed monitoring?<\/div>\n<div style=\"padding: 16px 20px; font-size: 14px; color: #444; line-height: 1.7;\">Yes. An incremental encoder can be factory-fitted on the non-drive end shaft extension of the YB2 8-pole as an option. The encoder itself must be Ex certified for the applicable zone and gas group (typically Ex d or Ex ec for Zone 1). The encoder signal cable exits the motor through a certified flame-path gland in a dedicated entry point on the terminal box or through a separate junction box mounted on the motor. The encoder output provides actual shaft speed feedback to the DCS or motor protection system, enabling shaft stall detection and speed monitoring independent of motor current. Specify the encoder type, signal format, and required Ex certification at the time of enquiry.<\/div>\n<\/div>\n<div style=\"border: 1px solid #dde3f0; border-radius: 8px; margin: 0 0 0; overflow: hidden;\">\n<div style=\"background: #f0f4ff; padding: 16px 20px; font-weight: bold; color: #1a3a6b; font-size: 15px;\">What documentation is supplied with each YB2 8-pole motor?<\/div>\n<div style=\"padding: 16px 20px; font-size: 14px; color: #444; line-height: 1.7;\">Each YB2 8-pole motor is supplied with: the Ex certification certificate (IECEx or ATEX as specified), the installation and maintenance instruction manual covering Ex-specific requirements, a dimensional drawing, a wiring diagram for the supply and any sensor connections, and the factory test record including dielectric withstand test, insulation resistance measurement, no-load test at rated voltage and frequency, and frame surface temperature measurement at the most thermally loaded point. For large-frame motors (frame 225 and above), a vibration test record at no-load is also included. All documents are in English as standard; other languages are available on request.<\/div>\n<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#1A3A6B 0%,#0d2247 100%); border-radius: 12px; padding: 40px 36px; text-align: center; margin: 0 0 20px;\">\n<h2 style=\"font-size: 24px; font-weight: bold; color: #fff; margin: 0 0 12px;\">Request a Quote for YB2 8-Pole Explosion-Proof Motors<\/h2>\n<p style=\"color: #cce0ff; margin: 0 0 24px; font-size: 16px;\">Specify power (kW), hazardous zone, gas group, impeller or driven equipment speed requirement, and certification market. Learn about our quality system on the <a style=\"color: #7eb3ff; font-weight: 600;\" href=\"https:\/\/industrialelectricmotor.net\/ko\/about\/\">About Us<\/a> page.<\/p>\n<p><a style=\"display: inline-block; background: #fff; color: #1a3a6b; font-weight: bold; font-size: 16px; padding: 14px 36px; border-radius: 8px; text-decoration: none;\" href=\"https:\/\/industrialelectricmotor.net\/ko\/contact-us\/\">Contact Korea Ever-Power<\/a><\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<div style=\"background: linear-gradient(135deg,#1A3A6B 0%,#0d2247 100%); color: #fff; padding: 48px 40px; border-radius: 12px; margin: 0 0 40px;\">\n<p style=\"font-size: 17px; color: #cce0ff; margin: 0 0 20px; max-width: 780px;\">Eight-pole flameproof squirrel-cage induction motor certified Ex d IIB T4 for Zone 1 and Zone 2 hazardous areas, running at approximately 720 rpm on 380 V 50 Hz. Maximum shaft torque per unit power in the YB2 range \u2014 the specification of choice for slow-speed direct-coupled agitators, classified area conveyors, and low-speed fan drives where minimising driven equipment complexity inside the hazardous zone is the primary design objective.<\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 12px;\"><span style=\"background: rgba(255,255,255,0.15); border: 1px solid rgba(255,255,255,0.3); border-radius: 20px; padding: 6px 16px; font-size: 13px; font-weight: 600;\">Ex d IIB T4 Certified<\/span><br \/>\n<span style=\"background: rgba(255,255,255,0.15); border: 1px solid rgba(255,255,255,0.3); border-radius: 20px; padding: 6px 16px; font-size: 13px; font-weight: 600;\">Zone 1 \/ Zone 2<\/span><br \/>\n<span style=\"background: rgba(255,255,255,0.15); border: 1px solid rgba(255,255,255,0.3); border-radius: 20px; padding: 6px 16px; font-size: 13px; font-weight: 600;\">Speed: ~720 rpm (8P)<\/span><br \/>\n<span style=\"background: rgba(255,255,255,0.15); border: 1px solid rgba(255,255,255,0.3); border-radius: 20px; padding: 6px 16px; font-size: 13px; font-weight: 600;\">Power: 1.5 \u2013 90 kW<\/span><br \/>\n<span style=\"background: rgba(255,255,255,0.15); border: 1px solid rgba(255,255,255,0.3); border-radius: 20px; padding: 6px 16px; font-size: 13px; font-weight: 600;\">Protection: IP55<\/span><br \/>\n<span style=\"background: rgba(255,255,255,0.15); border: 1px solid rgba(255,255,255,0.3); border-radius: 20px; padding: 6px 16px; font-size: 13px; font-weight: 600;\">Insulation: Class F<\/span><\/div>\n<\/div>","protected":false},"featured_media":23,"template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-143","product","type-product","status-publish","has-post-thumbnail","product_cat-explosion-proof-motors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/industrialelectricmotor.net\/ko\/wp-json\/wp\/v2\/product\/143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialelectricmotor.net\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/industrialelectricmotor.net\/ko\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/industrialelectricmotor.net\/ko\/wp-json\/wp\/v2\/media?parent=143"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/industrialelectricmotor.net\/ko\/wp-json\/wp\/v2\/product_brand?post=143"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/industrialelectricmotor.net\/ko\/wp-json\/wp\/v2\/product_cat?post=143"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/industrialelectricmotor.net\/ko\/wp-json\/wp\/v2\/product_tag?post=143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}