Y2 Series 4-Pole Three-Phase Asynchronous Motor

The Y2 Series 4-Pole Three-Phase Asynchronous Motor from Korea Ever-Power runs at a synchronous speed of 1500 rpm at 50Hz, spanning IEC frame sizes 63M through 315L with rated output from 0.12 kW to 132 kW. This is the most widely applied pole configuration in general industrial service, offering an optimal balance of speed, torque, efficiency, and frame compactness for pumps, conveyors, fans, compressors, machine tools, and material handling equipment worldwide.
Speed: 1500 rpm (50Hz)
Power: 0.12 – 132 kW
Poles: 4-Pole
Protection: IP54
Insulation: Class F
Voltage: 380V 50Hz

Y2 Series 4-Pole Motor — The Industry Standard 1500 rpm Drive

The Y2-*-4 four-pole motor series is the most commonly specified configuration in the three-phase induction motor range worldwide. At 50Hz, the synchronous speed is 1500 rpm — slow enough to couple directly to most industrial machinery without excessive speed reduction, yet fast enough to deliver high power density and compact dimensions. The 4-pole design represents the practical midpoint between the high-speed 2-pole and the lower-speed 6-pole and 8-pole configurations.

Korea Ever-Power manufactures 26 standard model ratings in the 4-pole configuration, covering the power range from 0.12 kW (Y2-63M1-4) through 132 kW (Y2-315L-4). Frame sizes span IEC 63M through 315L, with dimensional compliance to GB/T18680-2008 and JB/T8680-1998. All models are dimensionally interchangeable with Y-series, Y2-series, and equivalent IEC-frame motors from global manufacturers.

The 4-pole range is the basis from which our electromagnetic brake motors and VFD inverter duty motors are derived, sharing the same frame and shaft dimensions for complete compatibility with standard housings and driven equipment.three-phase-motor1

Y2 Series 4-Pole Technical Data — Full Model Range

The table below covers all 26 standard models in the Y2 4-pole range. Synchronous speed is 1500 r/min at 380V 50Hz. Actual full-load speed varies by frame size as shown. Current values apply to 380V rated voltage. Efficiency and power factor are measured at 100% rated load per GB/T18680-2008.

Model kW HP rpm Current (A) Eff (%) PF (cosφ) Vibration (mm/s) Noise dB(A) Ist/In Tst/Tn Tmax/Tn
Y2-63M1-4 0.12 0.16 1330 0.44 57 0.72 1.8 52 4.4 2.1 2.2
Y2-63M2-4 0.18 0.24 1330 0.62 60 0.73 1.8 52 4.4 2.1 2.2
Y2-71M1-4 0.25 0.34 1350 0.79 65 0.74 1.8 55 5.2 2.1 2.2
Y2-71M2-4 0.37 0.5 1350 1.12 67 0.75 1.8 55 5.2 2.1 2.2
Y2-80M1-4 0.55 0.75 1380 1.57 71 0.75 1.8 58 5.2 2.4 2.3
Y2-80M2-4 0.75 1 1380 2.05 73 0.76 1.8 58 6.0 2.3 2.3
Y2-90S-4 1.1 1.5 1390 2.8 76.2 0.77 1.8 61 6.0 2.3 2.3
Y2-90L-4 1.5 2 1390 3.7 78.5 0.79 1.8 61 6.0 2.3 2.3
Y2-100L1-4 2.2 3 1410 5.1 81 0.81 1.8 64 7.0 2.3 2.3
Y2-100L2-4 3 4 1410 6.7 82.6 0.82 1.8 64 7.0 2.3 2.3
Y2-112M-4 4 5.5 1440 8.8 84.2 0.82 1.8 65 7.0 2.3 2.3
Y2-132S-4 5.5 7.5 1450 11.7 85.7 0.83 1.8 71 7.0 2.3 2.3
Y2-132M-4 7.5 10 1450 15.6 87 0.84 1.8 71 7.0 2.3 2.3
Y2-160M-4 11 15 1460 22.5 88.4 0.84 2.8 75 7.0 2.2 2.3
Y2-160L-4 15 20 1460 30.0 89.4 0.85 2.8 75 7.5 2.2 2.3
Y2-180M-4 18.5 25 1470 36.3 90 0.86 2.8 76 7.5 2.0 2.3
Y2-180L-4 22 30 1470 42.9 90.5 0.86 2.8 76 7.5 2.0 2.3
Y2-200L-4 30 40 1470 58 91.4 0.86 2.8 79 7.2 2.0 2.3
Y2-225S-4 37 50 1480 70.4 92 0.87 3.5 81 7.2 2.0 2.3
Y2-225M-4 45 60 1480 85 92.5 0.87 3.5 81 7.2 2.0 2.3
Y2-250M-4 55 74 1480 103.3 93 0.87 3.5 83 7.2 2.0 2.3
Y2-280S-4 75 100 1480 139.9 93.6 0.87 3.5 86 7.2 2.0 2.3
Y2-280M-4 90 121 1480 167.4 93.9 0.87 3.5 86 7.2 2.0 2.3
Y2-315S-4 110 147 1486 201.0 94.5 0.88 3.5 93 6.9 2.1 2.2
Y2-315M-4 132 177 1486 240.4 94.8 0.88 3.5 93 6.9 2.1 2.2
Y2-315L-4 160 214 1486 287.8 94.9 0.89 3.5 97 6.9 2.1 2.2

Note: Ist/In — locked rotor current ratio; Tst/Tn — locked rotor torque ratio; Tmax/Tn — maximum torque ratio. All values at 380V 50Hz rated conditions per GB/T18680-2008.

Operating Conditions and Standards

Environmental Limits

  • Ambient temperature: −15°C to +40°C
  • Relative humidity: ≤ 90% (no condensation)
  • Altitude: ≤ 1,000 m above sea level
  • Frequency: 50 Hz standard (60 Hz on request)
  • Voltage tolerance: ±5% of rated value
  • Duty cycle: S1 continuous operation

Standards Compliance

  • GB/T18680-2008 — Y2 series technical conditions
  • JB/T8680-1998 — Chinese national standard
  • IEC 60034-1 — rotating electrical machines
  • IEC 60034-5 — IP protection classification
  • ISO 1680 — acoustic noise measurement
  • ISO 2373 — mechanical vibration grading

Motor Specifications

  • IP54 protection — dust and splash proof
  • Class F insulation (155°C limit)
  • Temperature rise per Class B standard (80K)
  • IC0141 TEFC forced cooling
  • Vibration ≤ 1.8 mm/s (frames 63–132)
  • Vibration ≤ 2.8 mm/s (frames 160 and above)

Why the 4-Pole Motor Is the Global Standard

The 4-pole configuration accounts for the majority of industrial motor installations worldwide. At 1500 rpm (50Hz), this operating speed closely matches the rated input speed of a very wide range of industrial gearboxes, pumps, fans, and blowers. Many NMRV worm gearboxes and helical gear reducers are specifically optimized for 1400–1500 rpm input, making the 4-pole motor the natural pairing for gearmotor assemblies.

From an electrical standpoint, 4-pole motors have a higher power factor than equivalent 6-pole or 8-pole designs at the same frame size, reducing reactive current drawn from the supply. The rotor inertia is lower than an 8-pole rotor of equivalent power, resulting in faster acceleration times — important for frequent start-stop applications such as conveyors, hoists, and packaging lines.

Efficiency performance improves substantially from small frames to large frames. The Y2-63M1-4 at 0.12 kW achieves 57% efficiency — typical for very small motors — while the Y2-315L-4 at 160 kW reaches 94.9%. For installations requiring IE3 or IE4 premium efficiency with identical frame dimensions, Korea Ever-Power offers the YE3 and YE4 equivalent series as direct dimensional replacements.

Typical Applications — 4-Pole 1500 rpm

Centrifugal Pumps
Industrial Fans
Air Compressors
Belt Conveyors
Gearmotor Drives
Machine Tools
Packaging Lines
Mixers and Agitators
Mining Equipment
HVAC Systems
Water Treatment
Printing Machinery

Application Scenes

Y2 4-Pole Motor Mining Conveyor Belt Drive Application

Mining Conveyor Drives

High-reliability belt conveyor and bucket elevator drives for quarrying, coal, and mineral processing operations

Y2 4-Pole Motor HVAC Pump Fan Drive

HVAC and Pump Rooms

Powering chilled water pumps, cooling tower fans, and air handling unit blowers in commercial and industrial buildings

Y2 4-Pole Motor Printing Press Machine Drive

Printing and Packaging

Main drive motors for offset printing presses, flexographic printers, laminating lines, and packaging machinery

Y2 4-Pole Motor Chemical Process Plant Drive

Chemical Process Plants

Reactor agitators, transfer pumps, and blower drives in chemical, pharmaceutical, and petrochemical facilities

4-Pole vs 2-Pole vs 6-Pole — Speed and Torque Comparison

Parameter 2-Pole 4-Pole 6-Pole 8-Pole
Synchronous Speed (50Hz) 3000 rpm 1500 rpm 1000 rpm 750 rpm
Typical Full-Load Speed 2800–2982 rpm 1330–1486 rpm 850–987 rpm 645–740 rpm
Relative Torque (same power) Low (1x) Medium (2x) High (3x) Highest (4x)
Frame Size (same power) Smallest Standard Larger Largest
Power Factor Highest High Medium Lower
Noise Level Higher Medium Lower Lowest
Best For Pumps, fans, compressors General purpose, gearmotor drives Conveyors, hoists Low-speed heavy loads

Highlighted column indicates the 4-pole range covered by this page. Torque multiples are approximate relative values for the same rated power output.

Frequently Asked Questions

Why does the Y2-63M1-4 run at 1330 rpm when the synchronous speed is 1500 rpm?

All induction motors run at slightly below synchronous speed under load — the difference is called slip. Small-frame motors (63M and 71M) have proportionally higher slip than large-frame motors because their rotor resistance is relatively higher. At full rated load, the Y2-63M1-4 runs at 1330 rpm (11.3% slip) while the Y2-315L-4 runs at 1486 rpm (0.9% slip). At no-load, all motors approach synchronous speed. Slip reduces as power output increases toward the larger frames.

Which NMRV worm gearbox sizes pair with Y2 4-pole motors?

Our NMRV worm gear reducers from size 025 through 150 are all designed for 1400–1500 rpm motor input. For example, an NMRV063 paired with a Y2-80M2-4 (0.75 kW, 1380 rpm) gives output ratios from 5:1 to 100:1 depending on gear ratio selected. The standard IMA flange adapter system means any Y2 motor with the correct frame can mount directly to the NMRV housing without an intermediate coupling.

What is the star-delta (Y-Δ) connection rule for Y2 4-pole motors?

At 380V supply: motors rated 3 kW and below use star (Y) connection; motors rated 4 kW and above use delta (Δ) connection. This results in the same phase voltage across each winding regardless of rating. For star-delta starting (Y-Δ starter), the motor must be delta-connected in normal operation; only motors rated 4 kW and above at 380V are suitable for Y-Δ starting. Motors at 660V supply always use delta connection across the full range.

Can I replace a Y-series motor with a Y2-4-pole motor of the same frame size?

Yes. The Y2 series was designed as a direct dimensional successor to the earlier Y series. IEC mounting dimensions including shaft height, shaft diameter, bolt hole pattern, and flange dimensions are maintained across the transition. In some cases, the Y2 motor at the same frame size offers slightly higher power output than the original Y motor due to improved winding design. Verify the nameplate power rating matches your load requirements before installation.

Is a soft-starter recommended for large Y2 4-pole motors?

For motors above 37 kW (Y2-225S-4 and larger), a soft-starter or star-delta starter is generally recommended to limit inrush current during starting. The Ist/In values in the data table show that these large-frame motors draw 7.2x rated current at locked rotor. A soft-starter reduces voltage during acceleration, limiting starting current to typically 3–4x rated current, reducing mechanical shock to driven equipment and preventing supply voltage dips that may affect other loads on the same network.

What is the maximum ambient temperature for standard Y2 4-pole motors?

Standard Y2 motors are rated for ambient temperatures up to 40°C. Above 40°C, derating is required: at 45°C reduce output power to approximately 95%, at 50°C to 90%, at 60°C to 82%. For permanent installation in high-temperature environments (steel mills, foundries, ovens), we recommend motors with H-class insulation or with external water cooling. Please specify ambient conditions when ordering for custom thermal assessment.

How do I calculate the rated torque of a Y2 4-pole motor from its nameplate data?

Rated torque (N·m) is calculated as: Tn = (P × 9550) / n, where P is rated power in kW and n is rated speed in rpm. For example, the Y2-132S-4 at 5.5 kW, 1450 rpm gives Tn = (5.5 × 9550) / 1450 = 36.2 N·m. Multiply by the Tmax/Tn ratio from the table (2.3) to find maximum transient torque = 83.3 N·m. This is useful for sizing couplings, belt drives, and gearbox input ratings.

Are IE3 premium efficiency 4-pole motors available in the same frame sizes?

Yes. Korea Ever-Power supplies the YE3 series (IE3 Premium Efficiency) and YE4 series (IE4 Super Premium Efficiency) with the same IEC frame dimensions as the Y2 series. The YE3 and YE4 motors are required in many markets under energy efficiency legislation (EU ErP 2021, China GB 18613-2020). They share identical mounting dimensions for direct substitution. Contact our sales team for YE3/YE4 availability and pricing by frame size.

Request a Quote for Y2 4-Pole Motors

Provide the model number (e.g., Y2-132S-4), required quantity, mounting type, and voltage to receive a factory-direct price with full technical datasheet within 24 hours.

Also explore: Full Motor Range · Worm Gear Reducers · Gearmotors

Informations complémentaires

Editor

Cxm